NOTE:

 In order to c omply  with UL 325, two s ets

of FAAC photobeams  mus t be ins talled. One s et
s hould be 6 in. outs ide the c los ed gate(s ) and ac t
as  a c los ing rev ers ing dev ic e. Another s et s hould
be 6 in. bey ond the s wing of the gate(s ) and ac t
as  an opening rev ers ing dev ic e. The ins taller is
res pons ible for determining the appropriate
mounting height.

22 23 24 25

1

2

3

4

5

6

7

8

N

L

9

10 11 12 13 14 15 16 17 18 19

115 V A C +/- 10%

or

230 V A C +6/ -10%

50-60 Hz

20 21

-

S TOP

OP E N

OP E N

(1 of 2)

24V

+

FS W

OP

C L

-

FS W

-

-

+

W .LIGHT

24 vdc

3 W

LOCK

E LE CTRIC  LOCK

1

2

1

2

3

4

5

1

2

3

4

5

1

2

FS W OP

FS W CL

Other safeties

LA MP

BL

U

E

MOTOR 1

C 1

M1

OP

C OM

C L

BL

U

E

MOTOR 2

C 2

M2

OP

C OM

C L

Page 16 

January,  200 4 

412 O pe rator And  

455 D  Control Panel I nst allatio n M anual   

Figure 14.  

The terminal strip wiring of 

the 455 D with photobeams 

You cannot check the motor’s direction of rotation 
without these circuits (jumpers) or the accessories.  

When properly prepared for testing, the LEDS FSWOP, 
STOP, and FSWCL should be illuminated (see figure 16 
on page 17).

 

 

WARNING! 

Running the operator—even for 

testing purposes—without a connected reversing 
device is potentially dangerous. Do not place 
yourself within the path of the moving gate 

during your test. 
 

Disengage the operator(s) with the Manual Release 

key (see operator installation manual), and open the 
gate by hand about halfway. 
Next, engage the operator(s) with the Manual Release 

key so that you can check the rotation of the motor
(s). 
 

To activate the operator(s) momentarily short across 
terminals 9 and 14. 

 
Turn on the main power and send an activating signal 
to the operator. The gate leaf (or leaves) should open. 

If a gate leaf closes, then you need to turn off the 
main power and reverse the connection of the red 
and black wires on terminal block J4 for the operator 

controlling that leaf. Then you need to recheck the 
rotation direction again. 
 

After having completed your test of the motor’s 
direction of rotation, replace any test circuits you 
installed (between terminals 11 and 16, between 12 

and 19, and between 13 and 19) with the proper 
reversing and stop devices. The instructions for 
installing such accessories follow. 

C

ONNECT

 O

THER

 D

EVICES

 

 
WARNING

! Turn the main power off before you 

make any electrical connections. 
 

P

OWER

  S

UPPLY

 

FOR

  A

CCESSORIES

: You can access a 24 

VDC output for supplying power to accessories  
through terminals 17 or 18, (+) and 14 or 15 or 16, (-

) on terminal block J1. In most cases, this source can 
be used to power 24 VDC accessories. 
 

N

OTE

: The 455 D control panel allows a 

maximum accessory load of 800 mA. 
 

R

EVERSING

  D

EVICES

Reversing devices include 

photocells, inductive loops, and so forth. All of the 
reversing devices should have contacts of the 
normally closed (N.C.) type. Where you connect a 

device depends on whether you want the device to 
operate during opening or during closing. 
 

N

OTE

: UL 

does not

 recognize the FAAC system 

with loop detectors or safety edges. FAAC 

photobeams must be used to comply with UL 
325. 

 

To wire photobeams, refer to page 19 (see FSWOP for 
opening photobeams, and FSWCL for closing 
photobeams). Photobeams must be connected as 

shown. See also page 19 for the wiring of inductive 
loops. If using more than one reversing device, they 
must be wired in series. 

T

HE

 455 D C

ONTROL

 P

ANEL

 I

NSTALLATION

 I

NSTRUCTIONS

 

Содержание 412 Compact

Страница 1: ...l the Operator 7 Install the 455 D Control Panel 10 Exploded View 412 12 412 Parts List 13 The 455 D Control Panel General Description 14 Installing the 455 D Control Panel 14 Connect the Main Power S...

Страница 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Страница 3: ...power before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation ther...

Страница 4: ...aximum leaf swing deg 110 Thrust and traction3 ft lb Nm 0 294 0 400 0 235 0 320 Stroke in cm 11 3 8 29 Rod speed 4 in sec cm sec 3 4 1 9 5 8 1 6 Thermal cut out deg F deg C 284 140 Operator dimensions...

Страница 5: ...s marked DX Be sure to install each on the proper gate leaf see Figure 2 2 Protective covers for the worm screw housing of the operator 1 Package of mounting hardware 2 Rear mounting brackets 2 Rear m...

Страница 6: ...anism that precisely controls the force transmitted to the gate leaf through the 412 Operator The Manual Release mechanism is a key operated device that disengages or engages the worm screw drive of t...

Страница 7: ...e where the operators are mounted The operator attached to the hinge on the left of the gate must be an SX model If the hinge is on the right side the DX model must be installed Installing the operato...

Страница 8: ...front mounting bracket with the short pin and one snap ring on the bottom and one snap ring on the top see Figure 9 11 13 16 in 30 cm 4 in 10 cm 5 29 32 in 15 cm Figure 6 The required dimensions of th...

Страница 9: ...Gate post or column Steel elbow A B C D F Centerline of gate leaf E Mounting Dimensions 90 deg Swing 110 deg Swing A 5 3 4 in 14 5 cm 4 7 8 in 12 5 cm B 5 3 4 in 14 5 cm 4 7 8 in 12 5 cm WARNING A an...

Страница 10: ...OPERATOR COVER Once the operator is attached to the gate leaf you next prepare the cover for installation Caution If you did not correctly establish the orientation of the gate leaf and properly inst...

Страница 11: ...d 455 D Control Panel Installation Manual 1 Operator Wire Gauges for Given Voltage 2 Control Panel 220 VAC 115 VAC 3 Photocell A 2 18 AWG A 2 18 AWG 4 Switch B 4 14 AWG B 4 14 AWG 5 Junction box see t...

Страница 12: ...Page 12 January 2004 412 Operator And 455 D Control Panel Installation Manual The 412 Compact Operator...

Страница 13: ...p Protective Cover SX 1 8 727147 End Cap Protective Cover DX 1 9 N A Nickel Plated Self Tapping Screw 3 5 x 9 5 mm 3 10 2705 Capacitor For 115 v 25 f 1 10 2707 Capacitor For 220 v 8 f 1 11 727216 Prot...

Страница 14: ...that the entire gate system meets all applicable electrical codes The installer should refer to the installation manual for a given operator for more information NOTE An installation is U L compliant...

Страница 15: ...e to 2 and the red wire to 3 Wire each leg of the capacitor supplied to terminals 2 3 Note If you want to delay the closing of one gate leaf in a two leaf gate design be sure to connect its operator t...

Страница 16: ...in power and send an activating signal to the operator The gate leaf or leaves should open If a gate leaf closes then you need to turn off the main power and reverse the connection of the red and blac...

Страница 17: ...e motors without a closed circuit between 11 14 The LED Indicators The nine light emitting diodes LEDs on the control panel can be used to check for the proper function of the devices attached to the...

Страница 18: ...he delayed leaf closes at the end of the closing time opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have installed are operat...

Страница 19: ...ev ices 14 9 C NO Rev ersing Photocells f or opening 1 2 1 2 3 4 5 17 13 19 14 17 Additional Reversing Devices TX RX 1 2 1 2 3 4 5 19 17 12 19 17 Additional Reversing Devices TX RX 1 2 19 12 17 15 Add...

Страница 20: ...he value that can be modified with keys and When you reach the last function press the F key to exit the program and the display resumes showing the status of the inputs The table on page 21 shows the...

Страница 21: ...ou sands from 0 to 99 thousand cy cles The displayed value is up dated as cycles proceed This func tion can be used to check use of the board or to exploit the Assistance Request function EXTRA WORK T...

Страница 22: ...ay stops flashing LEARNING OF OPERATING TIMES WARNING During the learning procedure the safety devices are disabled Therefore any and all traffic must be avoided in the path of the gate leaf s NOTE Pr...

Страница 23: ...and must be given to start the slow down phase When the gate operator reaches its positive stop the operator will automatically shut off An open command must be given to start closing gate operator 2...

Страница 24: ...g Reversing Device s Warning Light Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Ope...

Страница 25: ...s in hibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer trig gered No effect On Opened Closes both le...

Страница 26: ...directions before the automatic operator is installed An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the property...

Страница 27: ...OPENS BUT DOES NOT CLOSE SOLUTION Make sure you have selected the desired operating mode Verify that the reversing devices are working properly FSWOP and FSWCL should be illuminated except when a rev...

Страница 28: ...rdance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s...

Отзывы: