WARNINGS FOR THE INSTALLER - GENERAL SAFETY OBLIGATIONS 

IMPORTANT! To ensure the safety of people, it is important 
that all the instructions be carefully observed. Incorrect 
installation or  incorrect use of the product  could  cause 
serious harm   to people.

 

14 

Make sure that the earthing system is workmanlike built and 
connect the metal parts to it. 

Carefully read the instructions before beginning to install 
the product. 

15 

The automated system consists of an intrinsic anti-crushing 
safety device controlling the torque. However, you must 
check its action threshold as mentioned in the Regulations in 
point 10. 

Packing materials (plastic, polystyrene, etc.) must not be 
left within the reach of children, because these materials 
are potential danger sources. 

16 

Safety devices (EN 12978 standard) protect possible danger 
areas against 

Mechanical movement risks

. e.g. crushing, 

carrying away and shearing. 

Keep the instructions for future reference. 
 

17 

Use of at least one warning light is recommended for every 
system (e.g.  a built-in flashing light on the bollard head), a 
warning sign, in addition to the devices mentioned in point 
"16". 

This product was designed and built exclusively for the use 
indicated in this documentation. Any other use not 
expressly indicated could compromise the integrity of the 
product and/or be a source of danger. 

18 

For maintenance, strictly use original FAAC S.p.A. parts. 

FAAC S.p.A. declines any responsibility due to improper 
use or use other than the use for which the automated 
system  is intended. 

19 

FAAC S.p.A. declines all responsibility on the safety and 
efficient operation of the automated system, if system 
components not produced by FAAC S.p.A. are used. 

Do not install the equipment in an explosive atmosphere. 
the presence of gas or inflammable fumes is a serious 
danger to safety. 

20 

Do not in any way modify the components of the FAAC CITY 
automated system. 

For non-EU countries, to achieve an adequate safety level, 
the above mentioned standards must be observed in 
addition to the national standard references. 

21 

The installer must supply to the user Customer, all the 
information about the manual lowering of the bollard in  case 
of an emergency, and must hand over to the System User the 
warning handbook which accompanies the product. 

FAAC S.p.A. is not responsible for the non-observance of 
good  workmanship in installing FAAC CITY products and 
the relevant accessories, or for any deformation which 
may occur through use. 

22 

Do not allow children or persons to stay near the bollard, 
especially while it is in operation. 

10 

The installation must be carried out by observing the 
current regulations in force. 

23 

Keep radio controls or other pulse generators away from 
children, to prevent the automated system from being 
activated involuntarily. 

11 

Before attempting any action on the system, cut out the 
electrical power supply. 

24 

The  FAAC  CITY  bollard  must  be  transited  over  only  when  the 
device is completely lowered. 

12 

Install an all-pole switch on the electricity supply line for the 
automated system, with contact opening distance of 3 
mm or more. We advise you to use a 6A differential 
thermal breaker with all-pole switching. 

25 

The User must not in any way attempt to repair or to take 
direct action and must contact qualified authorised personnel 
only. 

13 

Make sure that a differential switch with a threshold of 
0.03A is installed upstream of the system. 

26 

Anything not expressly specified in these instructions is not 
permitted. 

 

 

 FAAC S.p.A. Via Benini, 1 40069 Zola Predosa Bologna (Italia) tel. +39 051 61724 www.faac.it

 

Содержание 275 H600

Страница 1: ...Automatic concealed bollards 275 H600 and 275 H800 Control station FAAC S p A Via Benini 1 40069 Zola Predosa Bologna Italia tel 39 051 61724 www faac it...

Страница 2: ...ller Bollard electrical connection Technical specifications for control station Control station lay out Dip switches on control board Connection terminal boards for control boards FAAC S p A Via Benin...

Страница 3: ...safety requirements of the following EEC directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendment 92 31 EEC and 93 68 EEC Additional information These products under...

Страница 4: ...sed 7 Do not install the equipment in an explosive atmosphere the presence of gas or inflammable fumes is a serious danger to safety 20 Do not in any way modify the components of the FAAC CITY automat...

Страница 5: ...movement the 1 st FAAC CITY is connected to the master unit the others are connected to additional slave units the enclosure dimension depends on the quantity of FAAC CITIES WALL FITTING ENCLOSURES F...

Страница 6: ...Input Out 24V d c OK Out 12V d c OK Out Green Traffic Lights Out Running Out Opened down Out Solenoid Valve Out Closed up Out Bollard fix Out Bollard mobile Out Acustic Bollard Pressure Sensor Input L...

Страница 7: ...rotection AUX Protection Out 24V c c OK Limit Switch Opening Input Pressure Sensor Input PF1 PF2 L3 L2 L1 Slave Slave Connection Master Slave Slave Slave Connection FAAC S p A Via Benini 1 40069 Zola...

Страница 8: ...or every type of movement to be controlled must be installed 230Vac Line Optional Emergency Button 230 V Optional Induttive Detector Prearrangement N C Prearrangement N C Trasformer 100 VA Faac City C...

Страница 9: ...P NO NC COM POWER 230V 2AT 5AT 1AT 2AT 2AT 2AT 1AT 55 50 20 21 46 49 42 39 38 37 36 40 43 34 33 32 35 30 29 28 25 24 23 22 26 27 31 41 48 47 44 45 53 52 51 54 19 4 5 6 8 9 7 10 13 14 12 15 16 17 18 11...

Страница 10: ...5 50 20 21 46 49 42 39 38 37 36 40 43 34 33 32 35 30 29 28 25 24 23 22 26 27 31 41 48 47 44 45 53 52 51 54 19 4 5 6 8 9 7 10 13 14 12 15 16 17 18 11 3 2 1 59 57 56 58 M PR 12V 12V 0 230V A C B 2AT 5AT...

Страница 11: ...re connected to the FAAC City Master equipment POWER CONNECTION MODEL 275 11 12 14 16 15 13 7 4 6 8 4 Control board terminals PR CABLE 2x1 CABLE 2x1 CABLE 4G1 CABLE 5G0 5 2 4 3 1 6 5 6G0 7 SHIELDED CA...

Страница 12: ...VERSING PRESSURE SWITCH ENABLED 5 REVERSING PRESSURE SWITCH DISABLED DIP SWITCH 1 position to be defined depending on the system s use and configuration if the safety devices are not used it must be p...

Страница 13: ...nals 20 and 21 to each other ON Position SAFETY DEVICES DISABLED the input for the safety devices terminals 20 21 is disabled If the FAAC CITY bollard does not rise you may temporarily disable the saf...

Страница 14: ...rd and return it to its low position ON Position REVERSING PRESSURE SWITCH DISABLED the function described above is disabled If the FAAC CITY bollard does not rise or if during the rise stage the boll...

Страница 15: ...nnection for flashing lighted sign 24 Vac intermittent output Terminals 20 21 22 23 connection for safety inductive detector Terminals 24 25 lowering command input Terminals 26 27 28 29 30 connection...

Страница 16: ...nnection to FAAC CITY low limit switch Terminal 15 connection for FAAC CITY intermittent buzzer Terminal 16 connection for flashing light incorporated into the head of FAAC CITY Terminal 17 common con...

Страница 17: ...FAAC S p A Via Benini 1 40069 Zola Predosa Bologna Italia tel 39 051 61724 www faac it...

Страница 18: ...18 www faac it Distributor s Stamp The descriptions and illustrations contained in the present manual are not binding FAAC reserves the right whilst leaving the main features of the equipments unalter...

Отзывы: