MASTER BOARD CONNECTION TERMINAL BOARD
Terminals 1-2-3= passing connection to 33-32-31 with protective fuse
Terminals 4-5-6-7-8 = connection for hydraulic power pack
Terminals 9-10 = Connection for automatic lowering device in the event of a 230V
power cut
Terminals 11-12 = connection to safety pressure switch
Terminal 13 = common contact for limit-switch - buzzer - flashing light
Terminal 14 = connection to FAAC CITY low limit-switch
Terminal 15 = connection for FAAC CITY intermittent buzzer
Terminal 16 = connection for flashing light incorporated into the head of FAAC CITY
Terminal 17 = common contact for limit-switch - buzzer - flashing light
Terminals 18-19 = connection for flashing lighted sign (24 Vac intermittent output)
Terminals 20-21-22-23 = connection for safety inductive detector
Terminals 24-25 = lowering command input
Terminals 26-27-28-29-30= connection for lowering command device
Terminals 31-32-33= passing connection to 3-2-1 with protective fuse
Terminals 34-35-36-37-38-39= connection for service transformer
Terminals 40-41-42 = 230V connection to 'traffic lights' 1
Terminals 43-44-45 = 230V connection to 'traffic lights' 2
Terminals 46-47-48= 'traffic lights' remote repetition (freed contact)
Terminals 49-50 = connection for emergency lowering push-button
Terminals 51-52= 230V connection to electronic circuit
Terminal 53 = not used
Terminal 54 = earth connection
Terminals 55-56-57-58-59 = connection for weekly/annual clock