![F5 Viprion Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/f5/viprion/viprion_manual_3088268057.webp)
DC platform power consumption
The actual amount of power draw from the DC power source depends on the type and number of blades and the redundancy
configuration. This table shows several possible configurations and the typical and maximum power draw.
Table 5: DC Mains Total System Power Draw
Number of power supplies
installed
Maximum system power
draw
Typical system power draw
Blade quantity and type
2
475W
400W
1 x PB100
2
800W
650W
2 x PB100
4
1225W
1000W
3 x PB100
4
1550W
1250W
4 x PB200
2
600W
500W
1 x PB200
2
1050W
850W
2 x PB200
4
1400W
1200W
3 x PB200
4
1750W
1550W
4 x PB200
Safety requirements
This equipment complies with the following requirements of the Low Voltage Directive 2006/95/EC.
EC Type Examination Certificates:
EN 60950-1:2006, 2nd Edition
Evaluated to all CB Countries
UL 60950-1, 2nd Edition, CSA C22.2 No. 60950-1-03
Important: Specifications are subject to change without notification.
EMC requirements
This equipment complies with the following EMC requirements.
USA
FCC Part 15 Class A
Japan
VCCI Class A
European Union
This equipment complies with the following requirements of the EMC Directive 2004/108/EC:
As Telecommunication Network Equipment (TNE) in Both Telecom Centers and Other Than Telecom Centers per
(as applicable):
Platform Guide: VIPRION | Platform Specifications | 57
Содержание Viprion
Страница 1: ...Platform Guide VIPRION MAN 0311 02...
Страница 2: ......
Страница 6: ...6 Platform Guide VIPRION Table of Contents...
Страница 38: ......
Страница 44: ......
Страница 61: ...Platform Guide VIPRION China RoHS Requirements 61...
Страница 62: ......
Страница 74: ...74 Platform Guide VIPRION Index...