Platform power specifications
This table lists power specifications for the 8900 platform.
Specification
Item
110VAC input: 397 W
Typical power draw (dual AC power supplies;
50% load; temp 25°C)
220VAC input: 409 W
48VDC input: 392 W
Typical power draw (dual DC power supplies;
50% load; temp 25°C)
220VAC input: 535 W
Maximum power draw (AC power)
48VDC input: 436 W
Maximum power draw (DC power)
110VAC input: 1536 BTU/hour
Typical heat generated (AC power)
220VAC input: 1604 BTU/hour
48VDC input: 1337 BTU/hour
Typical heat generated (DC power)
1826 BTU/hour
Maximum heat generated (AC power)
1487 BTU/hour
Maximum heat generated (DC power)
Important: Specifications are subject to change without notification.
Safety requirements
This equipment complies with the following requirements of the Low Voltage Directive 2006/95/EC.
EC Type Examination Certificates:
EN 6090-1:2006+A11:2009
IEC 60950-1:2005, 2nd Edition
CB Scheme
Master Contract 252302
UL 60950-1 2nd Edition, CSA C22.2 No.
60950-1-07
Important: Specifications are subject to change without notification.
51
Platform Guide: 8900
Содержание 8900
Страница 1: ...Platform Guide 8900 MAN 0330 03 ...
Страница 2: ......
Страница 6: ...6 Table of Contents ...
Страница 23: ...3 Open the hostconsh shell hostconsh 4 Open the AOM Command Menu Esc 23 Platform Guide 8900 ...
Страница 24: ......
Страница 32: ......
Страница 44: ......
Страница 48: ......
Страница 54: ......
Страница 56: ......
Страница 60: ......