| English
10
4. Non-intended use.
5.
Electrical system breakdown due to power of
the machine in a manner not compliant with the
electric and VDE regulations.
TECHNICAL DATA
Article Number
47 488
Model
ETIG 200 PULSE
Rated input voltage
V
230
Power frequency
Hz
50
Rated input capacity
kVA
7
Rated input current
A
33,5
Output no load voltage
V
82
Rated working voltage
V
TIG 18V /
MMA 27,2V
TIG welding current
A
10 - 200
MMA welding Current
A
10 - 180
Base value current
10%- 95%
Current rise time
s
0 - 15
Current drop time
s
0 - 25
Pulse frequency
Hz
0,2 - 200
Duty cycle
30%
Gas pre-flow time
s
0 - 5
Gas post flow time
s
1 - 15
Rated duty cycle
10%- 90%
Cooling type
Air
Effiency
η
≥ 85%
Power factor
cosφ
0,73
Insulation degree
H
Cover protection degree
IP21S
Net weight
kg
10
Dimensions (LxWxH)
cm
47,2 x 18,5 x
34,0
IDENTIFICATION (FIG. 1)
1. Control panel
2.
Ground lead output
3.
Possitive lead output
4.
MIG output
5.
ON/OFF switch (other side)
OPERATION
PREPARING THE UNIT
Unpacking and completing the assembly should
be done on a flat and stable surface, with enough
space for moving the machine and its packaging,
always making use of suitable equipment.
WARNING
Always unplug your machine from power source be
-
fore any adjustment.
OPERATING THE UNIT
WARNING
Connect ground lead as close to the area being weld-
ed as possible to ensure a good ground. Do not allow
any body part to come in contact with the welding
wire if you are in contact with the material being
welded, ground or electrode from another welder.
Do not drape cables over or around your body. Do
not overuse or overheat your welder. Allow prop
-
er cooling time between duty cycles. Do not point
torch at any body part of yourself or anyone else.
Always use this welder in the rated duty cycle to pre-
vent excessive heat and failure.
On the machine you will find the data table with
the below information:
X = Duty cycle
I1max = Maximum rated input current
I1eff = Maximum effective input current
I2 = Rated welding current
U0 = No load rated voltage
U1 = Rated input voltage
U2 = Loading voltage
NOTE
Suitable welding wire diameter should be selected
according to the welding job about to undertake.
MAINTENANCE AND CLEANING
WARNING
For your own safety, turn the switch off and remove
plug from power source outlet before any operation
of maintenance on the machine.
Keep your appliance clean. In order to avoid
overheating of the motor, regularly check the air
openings for any dust sticking on. After a longer
period of use, it is recommended to have the ma
-
chine checked by an authorized dealer service.
Connections and repairs of electrical equipment
may only be carried out by an electrician.
POWER CORD
To avoid shock or fire hazard, if the power cord is
worm or cut, or damaged in any way, have it re
-
place immediately. Electrical connection cables
often suffer insulation damage. Possible causes
are:
f
Punch points when connection cables are run
through window or door gaps.
f
Kinks resulting from incorrect attachment or lay
-
ing of the connection cable.
f
Cuts resulting from running over the connecting
cable.
f
Insulation damage resulting from forcefully pull
-
ing out of the wall socket.
f
Cracks through aging of insulation.
Such defective electrical connection cables must
not be used as the insulation damage makes them
extremely hazardous.
ETIG 200 PULSE