Note: a “hardware” timer of 3 seconds is implemented into the remote control to delay the
lighting of this diode and then avoid its untimely lighting at each powering.
Memory
1)
The green “
Memory
” diode stays
OFF
if no recording program is installed in the datalogger
or if the free memory space is lower than 5%.
2)
The red “
Memory
” diode stays
OFF
if no recording program is installed in the datalogger or if
the free memory space is higher than 25%.
3)
The green “
Memory
” diode lights fixed light if a recording program is installed in the
datalogger or if the free memory space is higher than 5%.
4)
The red “
Memory
” diode lights fixed light if a recording program is installed in the datalogger
or if the free memory space is lower than 25%.
Note: The “
Memory
” diode lights to indicate that the datalogger is ready to work, the color
shows the occupied memory space rate:
green
from 0 to 75%,
orange
from 75 to 95%,
red
over
95%. In case the memory is full, the red “
Error
” diode also lights.
Capture
1)
The yellow “
Capture
” diode stays OFF if no record has been realized since the opening of the
session.
2)
The yellow “
Capture
” diode lights fixed light if at least 1 record has been realized since the
opening of the session.
User
1)
Bicolor diode lighting accordingly to the status of its associated triggers or conditions (1 for
the green diode, 1 for the red diode)
Note: To avoid any untimely lighting of the « error » diode at the remote control powering,