background image

Pro

LM  RF

Temp. & RH Datalogger

Model No.: 6xx...

G-Tek Corporation Pvt. Ltd.

3, mahavir estate, karelibaug
vadodara-390 018
tel.: +91-265-2461912
email: [email protected]
url: www.gtek-india.com

OPERATING

MANUAL

       LM-H

Pro

Содержание LM Pro RF

Страница 1: ...LM RF Temp RH Datalogger Model No 6xx G Tek Corporation Pvt Ltd 3 mahavir estate karelibaug vadodara 390 018 tel 91 265 2461912 email info gtek india com url www gtek india com OPERATING MANUAL LM H...

Страница 2: ...s 5 1 4 Unpacking and inspection of LM Pro RF 5 1 4 1 Status LEDs 6 1 4 2 Display LCD 6 Installation 7 Operation 8 3 1 LM Pro RF Internal Schematics Diagram 8 3 2 LM Pro RF OPERATION 8 Troubleshooting...

Страница 3: ...List of Figures Figure 1 Front View of LM Pro RF 5 Figure 2 LCD Display 6 Figure 3 Schematic diagram of Set up of LM Pro RF 7 Figure 4 Internal Schematic diagram of LM Pro RF 8 Figure 5 5 VDC 1 2 Amp...

Страница 4: ...G Tek Corporation Pvt LTD 3 List of Tables LIST OF TABLES Table 1 Manual Layout 4 Table 2 Specification of LM Pro RF 11 Table 3 Sensor types and range 12 Table 4 LM Pro RF Order Code 13...

Страница 5: ...nd comparing it with the code on the LM Pro RF user can find out the installed options 1 2 LM PRO RF DESCRIPTION The LM Pro RF series of wireless data logger is a new RF based data logger measuring te...

Страница 6: ...INSPECTION OF LM PRO RF LM Pro RF is dispatched in a recyclable environment friendly package specially designed to give adequate protection during transit If the outer box shows sign of damage it shou...

Страница 7: ...ll be flickered with Heartbeat LED if Batch is ON at every 5 minutes Otherwise Storage LED will remain in OFF state if Batch is OFF 1 4 2 Display LCD The LCD display is 3 digit display shows the Tempe...

Страница 8: ...sing ethernet cable for communication Please refer the schematic diagram given in figure 3 for setting up the connection The PC must have GtekNet application to configure the Moderator for observing t...

Страница 9: ...pdated The STR led will flicker with HBT Led at 5 minutes time interval if Batch is running Otherwise STR led will remain in OFF state When the Batch is running recording indication is shown on LCD di...

Страница 10: ...LED will be flickered and Temp and RH will be updated If HRT LED does not flicker then contact to Gtek Corporation How is Alarm condition shown on LCD display When Alarm occurs it will be shown on LCD...

Страница 11: ...ard Accessories STANDARD ACCESSORIES 5 1 5 V DC 1 2 AMP ADAPTOR Figure 5 5 VDC 1 2 Amp Adaptor Input Voltage 100 240 V AC 0 35 Amp Operating Frequency 50 to 60Hz Output voltage 5V DC 1 2 Amp 5 2 ETHER...

Страница 12: ...ords totals Rollover Environmental Temperature Operation 5 C to 45 C Limiting 0 C to 50 C Storage 20 C to 60 C Humidity Operation 10 to 80 RH Non Condensing Storage 5 to 90 RH Non Condensing Altitude...

Страница 13: ...t LTD 12 Specification Table 3 Sensor types and range Parameter Sensor Range Accuracy Temperature Thermistor 20 to 60 C 0 5 C Temperature RH Solid state Temp 20 to 60 C 0 5 C RH 0 100 2 RH between 20...

Страница 14: ...er Code Series Input Type Power Supply Mounting Type Software Communication Interface 6 LM Pro RF 1 Temp 0 Battery Operated 0 Handheld 4 GtekNet Non Secure 6 Radio Frequency RF 2 Temp RH 1 Battery Mai...

Отзывы: