2.1.3.
Main characteristics of the CAN channel
2.1.4.
Protocol controller: INFINEON TWINCAN
-
Standard CAN 2.0B
-
Standard identifier 11 bits; extended 29 bits
-
Transmission / reception of data up to 8 bytes
-
Request for distant transmission (RTR)
-
Baud rate up to 1 Mbit/sec
-
Spy mode (no acknowledgement or error frame)
-
Reading of counters of internal errors
-
Detailed information in case of bus error
2.1.5.
High speed line interface: PHILIPS PCA82C251
-
Standard ISO 11898–24V
-
Baud rate up to 1 Mbit/sec
-
Channel up to 110 stations on the bus
-
Transmission in differential mode
-
Short circuit to ground and > 24V battery
UART2
CAN1
Diagnostic
connector
SAE J1962
Regulators
Quartz/
Oscillator
MCU 16 bits XC161CS
USB
connector
INPUT
ISO L
GPIO
UART1
CAN2
K2/LIN2 K4/LIN4
CAN1 HS/LS
CAN2 HS
K1/LIN1 K3/LIN3
USB controller
BUS
ADC