NAV SD 511 Scaling Decoder • Troubleshooting
79
Alarm
Cause
Remedy
Stream
Conflict
Multiple NAV endpoints are configured
to use the same video, audio, AES67, or
USB multicast IP address.
Reconfigure endpoint stream settings for
a unique stream address.
Stream
error
The decoder has lost reception of the
data stream for 2 seconds or more.
Check all network switches and routers
that support your NAV system for proper
multicast (IGMP) configuration.
Temperature
Interna
l
The NAV device is overheating.
Check the ambient temperature of the
NAV device installation location.
•
If greater than 104°F, (60ºC) use
HVAC system to lower ambient
temperature.
•
If ambient temperature is
104°F, (60°C) or less, check the
mounting location for nearby
equipment emitting excessive heat.
Ensure there is an air gap around
endpoint to allow adequate airflow.
Tie
Failure
The decoder failed to establish a tie with
the specified endpoint.
Debug the network connectivity between
the encoder and decoder.
USB
Over
-
current
One or more USB devices connected
exceed power budget (500 mA).
Remove one or more USB devices that
caused the over-current.