MLC 104 IP Plus Series • Special Applications
125
In this example, a 2-button switch is configured to have the MLC send e -mail alerts to alerts
to a security desk or to an administrative office when a button is pressed.
1.
In the Global Configurator
Advanced
Configuration
tab, configure the digital I/O
ports (ports 1 and 2 in this example) on the MLC
for digital input, as shown at right.
2.
Set up a monitor for each port.
a.
Click the
Monitor
tab (
).
b.
Click
Add Monitor
(near the bottom of the GC window). The
Monitored
Conditions Wizard
window appears.
c.
Type in the name of the first monitored condition:
Safety office alert
.
d.
Select
Conditions
in the
Monitored Conditions
area.
e.
Select
Digital I/O 1
as the
device.
f.
Select
Digital I/O Port is
Closed
as the
Status Command
.
g.
Click
Apply Condition
.
h.
Select
in the
Monitored
Conditions
panel.
i.
Create a notification e-mail if
you have not already done
so.
i.
Click
Email Manager
(the
Email Manager
window opens).
ii.
Type in the name,
subject, and main text.
iii.
Click
Add
.
iv.
Click
Done
to return
to the
Monitored
Conditions Wizard
window.
j.
If the contact person for this alert is not listed in the
Contacts
panel, create a
contact entry.
i.
Click
Contact Manager
. The
Contacts Manager
window opens.
ii.
Type in the recipient name, e-mail address, and company information.