4-3
ISM 824 Integration Scaling Multiswitcher • SIS
™
Programming and Control
Ethernet Link
The rear panel Ethernet connector on the switcher (figure 4-3) can be connected
to an Ethernet LAN or WAN. This connection makes SIS control of the switcher
possible using a computer connected to the same LAN or WAN.
12345678
RJ-45 Connector
Insert
Twisted
Pair Wires
Pins:
Side View
Straight-through Cable
(for connection to a switch, hub, or router)
End 1
End 2
Pin Wire Color
Pin
Wire Color
1
white-orange
1
white-orange
2
orange
2
orange
3
white-green
3
white-green
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
green
7
white-brown
7
white-brown
8
brown
8
brown
Crossover Cable
(for direct connection to a PC)
End 1
End 2
Pin Wire Color
Pin Wire Color
1
white-orange
1
white-green
2
orange
2
green
3
white-green
3
white-orange
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
orange
7
white-brown
7
white-brown
8
brown
8
brown
Figure 4-3 — RJ-45 connector pinout table
Ethernet connection
The cable can be terminated as either a patch cable or a crossover cable (figure 4-3)
and must be properly terminated for your application:
•
Patch (straight) cable
— Connection of the ISM to an Ethernet hub, router, or
switcher that also hosts a controlling computer
•
Crossover cable
— Direct connection between the ISM and a computer
Default address
To access the switcher via the LAN port, you need the switcher’s IP address. If
the address has been changed to an address comprised of words and characters,
the actual numeric IP address can be determined using the front panel (see
Comm Settings menu” in chapter 3, “Operation and Setup
“Ping to determine the switcher’s IP address”
or “Ping to determine Extron IP
address” in appendix A, “Ethernet Connection”
, for more details). If the address
has not been changed, the factory-specified default is 192.168.254.254.
Symbols
Symbols (
X/
values), defined on page 4-4, are used throughout the discussions of the switcher-
initiated messages that begin on the next page and the command/response table that begins
on page 4-8. The symbols represent variables in the switcher-initiated messages and the
command/response table fields.
Содержание ISM 824
Страница 1: ...ISM 824 Integration Scaling Multiswitcher 68 1123 01 Rev A 02 08...
Страница 4: ...ISM 824 Integration Scaling Multiswitcher ii...
Страница 22: ...Introduction cont d ISM 824 Integration Scaling Multiswitcher Introduction 1 8...
Страница 130: ...ISM 824 Multiswitcher Software cont d ISM 824 Integration Scaling Multiswitcher ISM 824 Multiswitcher Software 5 28...
Страница 151: ...ISM 824 Integration Scaling Multiswitcher A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer...
Страница 158: ...Ethernet Connection cont d A 8 ISM 824 Integrated Scaling Multiswitcher Reference Information...
Страница 159: ...ISM 824 Integration Scaling Multiswitcher B Appendix B Reference Information Specifications Part Numbers and Accessories...