HAI 100 4K PLUS • SIS Commands
9
SIS Commands
This section provides information on:
•
•
Simple Instruction Set (SIS) Control
•
Command and Response Table for SIS Commands
Connecting a Control Computer
Connect a control PC to the front panel config port using a USB cable (see
on page 3). Use a communication utility, such as Extron DataViewer, to send SIS
commands and view the responses.
Simple Instruction Set (SIS) Control
Host-to-Device Communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When a command is valid, the
HAE 100 4K Plus device executes the command and sends a response to the host device.
All responses from the device to the host end with a carriage return and a line feed
(CR/LF =
]
), which signals the end of the response character string. A string is one or
more characters.
Error Responses
When the device receives a valid SIS command, it executes the command and sends a
response to the host device. If the device is unable to execute the command because the
command is invalid or it contains invalid parameters, it returns an error response to the host.
The error response codes and their descriptions are as follows:
E10
– Invalid command
E13
– Invalid parameter
Timeout
Pauses of 10 seconds or longer between command ASCII characters result in a timeout.
The command operation is aborted with no other indication.
Using the Command and Response Table
The
Command and Response Table for SIS Commands
Command and response examples are shown throughout the table. Symbols are used
throughout the table to represent variables in the command and response fields. Use the
ASCII to HEX conversion table on the next page with the command and response table.