Furniture mounting

Mount any of the 1" high, quarter-rack width units under a 
desk or podium using the optional Extron MBU 125 under desk 
mounting kit (part #

70-077-01

) as follows:

1

If rubber feet were previously installed on the bottom of 

the unit, remove them.

2

Secure the mounting brackets to the unit with the provided 

machine screws (figure 2-2).

 

Figure 2-2 — Under-desk mounting the unit

3

Hold the unit with the brackets attached against the 

underside of the table or other furniture.  Mark the location 

of the screw holes of the bracket on the mounting surface.

4

Drill four pilot holes, each 3/32" (2 mm) in diameter by 

1/4" deep (6.3 mm) deep in the mounting surface at the 

marked screw locations.

5

Insert provided #8 wood screws into the four pilot holes.  

Tighten each screw into the mounting surface until just less 

than 1/4" (6.3 mm) of the screw head protrudes.

6

Align the mounting screws with the slots in the brackets 

and place the unit against the surface, with the screws 

through the bracket slots.

7

Slide the unit slightly in or out, then tighten all four screws 

to secure the unit in place (figure 2-2).

Through-desk mounting

Mount any of the 1" high, quarter-rack width units through a 

desk or podium using the optional Extron MBD 129 through 
desk mounting kit (part #

70-077-02

) as follows:

1

If rubber feet were previously installed on the bottom of 

the unit, remove them.

2

Secure the brackets to the unit with the provided 

machine screws (figure 2-3).  Leave the screws slightly loose.

 

Figure 2-3 — Through-desk mounting the unit

3

Hold the unit and brackets on the underside of the surface 

to which you are mounting the device and mark the four 

screw holes and the table material to be removed.

4

Cut out and remove the table material.  Test the fit by 

inserting the front of the device through the hole.  If 

necessary, use a rasp or coarse file to enlarge the hole.

5

Drill four pilot holes, each 3/32" (2 mm) in diameter by 

1/4" deep (6.3 mm) deep, in the locations that you marked 

in step 

3

.

6

Using the provided four #8 wood screws, attach the 

brackets to the mounting surface.

7

Slide the device in or out until it is in the desired position.  

Tighten the screws installed in step 

2

.

Содержание FOXBOX 4G Rx VGA

Страница 1: ...31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 400 883 1568 Inside China Only 86 21 3760 1568...

Страница 2: ...sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels Netzkabel sollten stets so verl...

Страница 3: ...e undesired operation The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates...

Страница 4: ...to receiver Rx is required for video audio and serial command transmission But if you connect only one fiber optic cable or if your transmitter is configured to daisy chain the optical signal system f...

Страница 5: ...t also be in normal configuration N For normal configuration with serial return perform step 7 and skip step 8 For daisy chain configuration skip step 7 and perform step 8 Step 7a normal configuration...

Страница 6: ...rror responses 3 5 Timeout 3 5 Using the command response table 3 5 Command response tablefor SIS commands 3 6 Windows Based Program Control 3 14 Installing the software 3 14 Starting the program 3 14...

Страница 7: ...or FOX 500 transmitter or daisy chained receiver and outputs a single link of DVI video audio and RS 232 serial commands Also can either Receive an RS 232 return from a controlled device and send it t...

Страница 8: ...h Digital Content Protection HDCP N A FOXBOX 4G Tx VGA transmitter is fully compatible with a FOXBOX 4G DVI Rx receiver A FOXBOX 4G DVI Tx transmitter is fully compatible with a FOXBOX 4G Rx VGA recei...

Страница 9: ...mitters and receivers rear panels have discrete outputs that indicate if either of the fiber optic links have suffered a loss of the light signal Windows based control program For RS 232 remote contro...

Страница 10: ...FOXBOX 4G Tx Rx Introduction Introduction cont d 1 8 FOXBOX 4G Tx Rx 2 Chapter Two Installation and Operation Mounting the Unit Connections Operation...

Страница 11: ...t a hazardous condition is not achieved due to uneven mechanical loading 4 Circuit overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect tha...

Страница 12: ...nd place the unit against the surface with the screws through the bracket slots 7 Slide the unit slightly in or out then tighten all four screws to secure the unit in place figure 2 2 Through desk mou...

Страница 13: ...hen you are making connections for the transmitter from existing audio cables A mono audio connector consists of the tip and sleeve A stereo audio connector consists of the tip ring and sleeve Tip Sle...

Страница 14: ...to any other compatible Extron FOX device Tx Link and Rx Link LEDs When lit the link is active light is received g Configuration port Connect a controlling device such as a PC to this port via a 2 5...

Страница 15: ...or FOXBOX 4G Rx VGA only Connect an analog VGA UXGA RGB video display to this 15 pin HD female connector N You can set the receiver to output the desired video format RGBHV or RGsB RGBHV is the defaul...

Страница 16: ...or DVI FOXBOX 4G DVI LED This LED lights on the receiver when the transmitter detects a signal on its video input as follows RGB LED Horizontal sync H for RGBHV video or Green Sync on green G for RGs...

Страница 17: ...Function Pin TX RX Gnd Transmit data Receive data Signal ground NOTE Cross the Tx and Rx lines once between the source and the target ALARM Tx Rx 1 2 RS 232 OVER FIBER Figure 2 8 RS 232 connectors N...

Страница 18: ...RS 232 up to 250 76 m away See chapter 3 Remote Control for definitions of the SIS commands serial commands to control the transmitter via this connector and Windows based program control Power supply...

Страница 19: ...e routed and connected properly and that all display devices have identical resolutions and refresh rates If your problems persist call the Extron S3 Sales Technical Support Hotline See the contact nu...

Страница 20: ...e host end with a carriage return and a line feed CR LF which signals the end of the response character string A string is one or more characters Symbol definitions Symbols variables defined on the ne...

Страница 21: ...the receiver s DIP switch settings occurs N Only DIP switch 1 the first X has any effect on the system operation When the switch is on up the receiver is in daisy chain mode Error responses When the u...

Страница 22: ...scription Horizontal shift Set a horizontal position X H HphX Set horizontal centering to X Increment position H HphX Shift the image one pixel to the right Decrement position H HphX Shift the image o...

Страница 23: ...sync frequency View input frequency 1LS X1 X1 List the input frequency as X1 kHz horizontal and X1 Hz vertical Command response table for SIS commands continued Command ASCII Command host to unit Res...

Страница 24: ...itional description Test pattern N You must have a video input connected and the transmitter Tx to receiver Rx fiber cable for the receiver to output a selected test pattern The test pattern turns off...

Страница 25: ...ix A for part numbers Request other unit s part number 1N 60 nnn nn See appendix A for part numbers Show link 1 2 status 1S or 2S X1 0 light link not received at receiver 1 light received Show input v...

Страница 26: ..._Extenders directory and it places four icons into a group folder named Extron Electronics FOX Extender WCP The four installed icons are Check for FOX Extender updates FOX Extender WCP FOX Extender He...

Страница 27: ...program s Link 2 indicator will not show green detected whether the transmitter detects the link or not The Status area also shows to which unit the controlling PC is connected the FOXBOX 4G model mul...

Страница 28: ...ition values Output Configuration area Sync Format radio buttons The FOXBOX 4G receiver outputs RGBHV or RGsB video depending on the input to the transmitter only The radio buttons in this area have n...

Страница 29: ...ducts to receive the fiber optic signal as those products can be configured to output audio at the professional level Firmware upgrade Firmware can be upgraded for each unit via either of that unit s...

Страница 30: ...ad The File Loader reports This process could take several minutes Please wait and then displays the status of the upload 9 When the Firmware Loader reports Transfer complete click the Exit button 10...

Страница 31: ...FOXBOX 4G Tx Rx Remote Control Remote Control cont d 3 24 FOXBOX 4G Tx Rx A Appendix A Reference Information Specifications Part Numbers...

Страница 32: ...e is approximate These are typical distances The maximum distance may be greater than these typical numbers depending on factors such as fiber type fiber bandwidth connector splicing losses modal or c...

Страница 33: ...Vp p Video delay 1 2 frames Audio Gain Range Adjustable 18 dB to 10 dB Default Unbalanced output 0 dB Frequency response 20 Hz to 20 kHz 0 5 dB THD Noise 0 10 1 kHz at nominal level S N 80 dB at maxim...

Страница 34: ...lbs 0 6 kg per pair Shipping weight 3 lbs 2 kg per unit 6 lbs 3 kg per pair Vibration ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety CE CUL FDA Class 1 UL EMI EM...

Страница 35: ...m to 30 4 m molded 26 238 nn VGA M M BK 3 to 100 0 9 m to 30 4 m backshell 26 238 nn VGAP M M MD 3 to 25 0 9 m to 7 6 m molded plenum 26 439 nn VGAP M M BK 35 to 100 10 6 m to 30 4 m backshell plenum...

Отзывы: