Страница 1: ...User Guide DTP2 T 202 FB DTP Systems Two input Universal Twisted Pair Transmitter for Floor Boxes 68 2985 01 Rev A 12 20...

Страница 2: ...encia 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la pr sence l int rieur...

Страница 3: ...IP Link Key Minder LinkLicense LockIt MediaLink MediaPort NAV NetPA PlenumVault PoleVault PowerCage PURE3 Quantum ShareLink Show Me SoundField SpeedMount SpeedSwitch StudioStation System INTEGRATOR Te...

Страница 4: ...shielded twisted pair STP cables but to ensure FCC Class A and CE compliance STP cables and STP Connectors are required La technologie extension paires torsad es fonctionne avec les c bles paires tor...

Страница 5: ...itten in the font shown here Reply from 208 132 180 48 bytes 32 times 2ms TTL 32 C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH R Data STX Comman...

Страница 6: ......

Страница 7: ...loor Box 12 MK Electric CableLink Plus Modular Floor Box 13 Electraplan or PUK Floor Box 13 Connection and Wiring Details 14 Power Supply Wiring 14 Serial and IR Port Connectors 16 TP Cable Terminatio...

Страница 8: ...DTP2 T 202 FB Contents viii...

Страница 9: ...g inputs The selected digital video input including embedded digital audio An optional analog audio input Bidirectional RS 232 and infrared IR control signals The switcher and a compatible receiver ex...

Страница 10: ...K Display PC PC 4K Media Player Extron DTP2 T 202 FB Transmitter CATx Cable up to 330 100 m CATx Cable up to 330 100 m CATx Cable up to 330 100 m AV LAN Ethernet RS 232 AV LAN Audio Handheld Microphon...

Страница 11: ...DTP2 or legacy DTP receiver can output balanced and unbalanced audio allowing streamlined integration within an AV system Bidirectional RS 232 and IR insertion for AV device control Control and IR sig...

Страница 12: ...mmages mat riels 1 Check that the installation of the floor box meets government building electrical and safety codes 2 Install the floor box according to the instructions of the manufacturer 3 Prepar...

Страница 13: ...Software on page 28 Adapter Plates Each model of floor box requires a specific pair of provided adapter plates to secure the device to the box see the table below for the appropriate adapter plates t...

Страница 14: ...gure 3 Figure 3 Installing an Adapter Plate 995241 Shown into a Mounting Slot NOTES Install adapter plates in mounting slots of the same position in the floor box The MK Electric CableLink Plus Single...

Страница 15: ...ate Side Panel Features Connectors and Switches Below the Adapter Plates OVER TP OUT IR RS 232 RS 232 REMOTE POWER SEND POWER 12V 1 4A MAX OFF HDBT DTP G Rx Tx Rx Tx G Rx Tx LINK SIG e D T P 2 T 2 0 2...

Страница 16: ...ff droite Si l interrupteur n est pas positionn sur off vous risquez d entra ner la d faillance de l appareil DTP connect NOTES When the following switches are set as follows one power supply can powe...

Страница 17: ...t on the powered unit to enable sending power to the unpowered unit Set the toggle switch to the Off position right on the DTP2 unit that is to receive power F TP function switch HDBT DTP ATTENTION Po...

Страница 18: ...re making connections for the switching transmitter from existing audio cables A mono audio connector consists of the tip and sleeve A stereo audio connector consists of the tip ring and sleeve The an...

Страница 19: ...s are sent simultaneously to both the command that reaches the processor first is handled first B Reset button Initiates two levels of RESET switcher reset For the different reset levels press and hol...

Страница 20: ...e 995242 adapter plate on top of one of the 995241 adapter plates MK Electric CableLink Plus Single Pan Floor Box D TP T 20 2 FB PO WE R D TP T FB 33 2 RE MO TE RS 23 2 G Rx Tx 12V A MA X XT PO WE R D...

Страница 21: ...MO TE RS 23 2 G Rx Tx 12V A MA X XT P OU T 995244 995244 Figure 13 Mounting the Unit into an MK Electric CableLink Plus Modular Floor Box Electraplan or PUK Floor Box DT P T 202 FB PO WE R XT P T FB...

Страница 22: ...nd l alimentation est branch e The length of exposed wires is important The ideal length is 3 16 inch 5 mm Any longer and the exposed wires may touch causing a short circuit between them Any shorter a...

Страница 23: ...s les cavit s murales The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI NFPA 70 article 725 and the Canadian Electrical Code part 1 section...

Страница 24: ...can be easily pulled out even if tightly fastened by the captive screws Do not tin the power supply leads before installing them in the connector Tinned wires are not as secure in the connector and co...

Страница 25: ...Non Plenum 1000 feet 305 meters spool 22 236 03 XTP DTP2 24P 1000 Plenum 1000 feet 305 meters spool 22 235 03 XTP DTP2 24 Plug Package of 10 101 005 02 If not using XTP DTP2 24 cable at a minimum Extr...

Страница 26: ...necteur HDMI Le blindage auquel elle est attach e est tr s fin et peut facilement tre d nud 4 Loosely place the included tie wrap around the HDMI connector and the LockIt lacing bracket as shown 4 5 W...

Страница 27: ...ode Use the recessed Reset button on the top panel of the transmitter see item B on page 11 to initiate two levels of reset as follows Reset to factory default condition Cycle unit power off and on wh...

Страница 28: ...Port below The Remote RS 232 port and Configuration port are independent of one another A Remote RS 232 port connection and a Configuration port connection can be active at the same time Serial port...

Страница 29: ...202 FB Vx xx 60 nnnn nn The transmitting receiver issues the copyright message when it first powers on Vx xx is the firmware version number and 60 nnnn nn is the part number Switcher Error Responses W...

Страница 30: ...Switch mode Set manual switch mode E0AUSW Ausw0 Set switch mode to normal Set auto switch mode with DisplayPort priority E1AUSW Ausw1 Set switch mode to auto DisplayPort Automatically selects the Disp...

Страница 31: ...Disable HDCP notification EN0HDCP HdcpN0 Enable HDCP notification EN1HDCP HdcpN1 Show green screen View HDCP notification mode ENHDCP X Verbose 2 3 HdcpNX TMDS output format Set TMDS output format EX...

Страница 32: ...audio mute status is X1 Audio routing selection Set input audio format EIX X1 AFMT AfmtIX X1 View input audio format EIX AFMT X1 Verbose 2 3 AfmtIX X1 Disable mute output embedded audio Toggle embedde...

Страница 33: ...scription 2I DTP2 HDMI DP FB Tx SUPPORT 4K60 Verbose 2 3 Inf02 DTP2 HDMI DP FB Tx SUPPORT 4K60 Query controller firmware version Q X1 Query firmware version with build Q X2 Verbose mode NOTE If tagged...

Страница 34: ...output downstream sink EO1 15 X4 DCEC or EO1 15 X5 DCEC DceO1 X5 X5 X5 X4 command or X5 data KEY X4 CEC mode X4 CEC status X4 Source logical address X4 Destination logical address X4 CEC command X5 Se...

Страница 35: ...essages Ceco1 0F 32 65 6E 67 1 TV broadcast command to set the meny language to English eng Ceco0 0E 1 TV pings us to confirm we are still there NOTE Asynchronous received data messages from the CEC i...

Страница 36: ...p bit The program is compatible with Windows 7 and later Installing the Software The PCS minimum version 4 7 0 or newer is required for the transmitter and Firmware Loader are available on the Extron...

Страница 37: ...ed filtering letter see figure 20 1 to jump to the nearest page of downloads 4 Click Download for the desired software or firmware package to download 2 The Log in dialog box appears see figure 21 1 1...

Страница 38: ...wser choice and its security settings 8 For a firmware upgrade exit this procedure and update the transmitter firmware as described in the PCS Help file 9 Follow the on screen instructions The install...

Страница 39: ...oftware opens to the Device Discovery screen see figure 23 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Figure 23 Device Discovery Screen 2 Select click the desired DTP2 T F...

Страница 40: ...3rd Floor South Tower 160 Jan Smuts Avenue Rosebank 2196 South Africa This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse...

Отзывы: