DTP T EU 332, DTP T EU 232, DTP T MK 332, and DTP T MK 232 • Installation and Operation
14
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances
up to 330 feet (100 meters) (DTP T EU 332 and DTP T MK 332) or 230 feet (70 meters)
(DTP T EU 232 and DTP T MK 232) and reduce transmission errors.
•
Use the following Extron XTP DTP 24 STP cables and DTP 24 connectors for the best
performance:
•
XTP DTP 24/1000
Non-Plenum 1000’ (305 meters) spool
22-236-03
•
XTP DTP 24P/1000
Plenum 1000’ (305 meters) spool
22-235-03
•
XTP DTP 24 Plug
Package of 10
101-005-02
•
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
•
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
•
Use no more than two pass-through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass-through points are
required, use CAT 6 or 6a shielded couplers and punch down connectors.
NOTE:
When using STP cable in bundles or conduits, consider the following:
•
Do not exceed 40% fill capacity in conduits.
•
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
•
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
•
Separate twisted pair cables from AC power cables.
IR and RS-232 Connector Wiring
Figure 12 shows how to wire the Remote RS-232 and Over DTP RS-232 and IR
connectors.
Rx
Tx
Tx
Rx
Gnd
Gnd
IR Device
RS-232 Device
Tx
Rx
G
RS-232
R
E
M
O
T
E
Tx
Rx
GT
xR
x
RS-232
O
V
E
R
T
P
IR
Figure 12.
IR and RS-232 Connectors Wiring
NOTES:
•
The IR Tx and Rx line pair and the RS-232 Tx and Rx line pairs must each cross
once between their connectors and the source or destination.
•
The length and preparation of exposed wires is important (see the second and third
power connector
CAUTIONS
on the next page for details).