Extron electronics ACP 106 EU Скачать руководство пользователя страница 7

 

7

1

1

2

2

3

3

VOLUME

MUTE

PC

MIC

PROGRAM

X

MK Wall Box

Wall

Metal Mounting
Bracket

Plastic 
Faceplate

ACP 106 MK

VOLUME

MUTE

PC

MIC

PROGRAM

X

Wall Box

Plastic 
Faceplate

Metal Mounting
Bracket

ACP 106 EU

1

1

3

3

2

2

Step 8: Mounting the ACP 106 EU/MK

Prior to mounting:

1. 

Feed all device cables through the wall or furniture.

NOTE:

  If the unit is not installed in a mud ring, the plastic spacer must be installed. The spacer positions the unit to allow 

the plastic faceplate to attach properly and securely. 

2. 

Ensure the cables are connected to the ACP 106 EU/MK rear panel.

Mounting ACP 106 EU or ACP 106 MK Units to an Electrical Wall Box

The ACP 106 EU can be mounted in any standard 1-gang EU electrical junction box. The ACP 106 MK can be mounted in any 
standard 1-gang MK electrical junction box. 

NOTES:

• 

The electrical wall box is not provided and must be purchased separately.

• 

Install the electrical wall box by following the instructions provided by the manufacturer.

• 

Use the metal mounting bracket provided with ACP unit.

To mount an ACP 106 EU/MK:

1. 

Decide where the panel will be located. Take into consideration 
the position of wall studs and windows that could obstruct cable 
runs.

2. 

Install the electrical wall box (see 

1

 in the figure to the right) by 

following the instructions provided by the manufacturer. Attach 
the provided metal mounting bracket (

2

) using the two provided 

screws.

NOTES:

• 

The metal mounting brackets provided with the 
EU and MK models are different and are not 
interchangeable.

• 

Ensure the bracket is in the correct orientation (with 
the side marked “Front” facing away from the wall.

• 

The EU model is attached with screws at the top and 
bottom.

• 

The MK model is attached with screws on both the 
sides. 

3. 

Disconnect power from all devices at the source and run cables 
through the hole in the wall. Pass them through the metal mounting 
bracket and plastic faceplate and connect them to the rear panel 
captive screw connectors (see 

Step 5: Cable All Devices

 

on 

page 4).

4. 

Set the DIP switches to give the panel a unique ID number (see 

Step 4: Set Bus ID Addresses

 

on page 3).

5. 

Insert the ACP 106 EU/MK into the plastic faceplate (

3

) and press 

the entire assembly into the metal mounting bracket (

2

). The device 

is secured to the metal mounting bracket by two catches (one on each 
side) and holds the wallplate in place.

Содержание ACP 106 EU

Страница 1: ...m and Installation When planning to install an ACP system consider how many ACP panels to use maximum cable distance and mounting see the ACP 106 EU and ACP 106 MK product pages at www extron com for...

Страница 2: ...g accessibility of the button panel such as height from the floor distance from obstructions and how far a user must reach to press the buttons For guidelines see sections 307 Protruding Objects and 3...

Страница 3: ...e DMP Plus a PS 1220EB power inserter or an Extron 12 VDC power supply Bus ID Address DIP Switches Use these DIP switches to set the six bit binary bus address for the ACP 106 EU MK Each ACP connected...

Страница 4: ...se a power supply supplied or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the unit Utilisez toujours un...

Страница 5: ...ct the power pin to any device that is already powered by the DMP Plus or by an additional power supply 3 16 5 mm Max Figure 4 Cabling ACP Devices with a PS 1220EB Power Inserter ACP 106 EU Rear Panel...

Страница 6: ...n Single LED bicolor No power eBUS cable broken Off Off Device is receiving power and communicating correctly with the DMP Plus Lights solidly Lights green Device is receiving power but cannot communi...

Страница 7: ...here the panel will be located Take into consideration the position of wall studs and windows that could obstruct cable runs 2 Install the electrical wall box see 1 in the figure to the right by follo...

Страница 8: ...ads protruding approximately 1 8 inch 3 18 mm from the surface of the spacer 5 Rotate the metal mounting bracket as necessary to ensure that the device will be aligned correctly on the mounting surfac...

Отзывы: