Extron electronics ACP 106 EU Скачать руководство пользователя страница 2

 

2

ACP 106 EU/MK • Setup Guide (Continued)

Step 2: Prepare the Installation Site

ATTENTION:

 

• 

Installation and service must be performed by authorized personnel only.

• 

L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.

• 

Extron recommends installing the ACP 106 EU/MK into a grounded, UL Listed electrical junction box.

• 

Extron recommande d’installer le ACP 106 EU/MK dans un boîtier d’encastrement électrique mis à la terre, listé UL.

• 

If the ACP 106 EU/MK will be installed into fine furniture, it is best to hire a licensed, bonded craftsperson to cut the 
access hole and perform the physical installation so the surface will not be damaged.

• 

S’il est prévu d’installer le ACP 106 EU/MK dans du beau mobilier, il est préférable de faire appel à un artisan autorisé et 
qualifié pour couper le trou d’accès et réaliser l’installation de telle façon que la surface ne soit pas endommagée.

• 

Follow all national and local building and electrical codes that apply to the installation site.

• 

Respectez tous les codes électriques et du bâtiment, nationaux et locaux, qui s’appliquent au site de l’installation.

NOTE:

  For the installation to meet UL requirements and to comply with National Electrical Code (NEC), the ACP 106 EU/MK 

must be installed in a UL Listed junction box. The end user or installer must furnish the junction box. It is not included with 
the ACP 106 D.

Americans with Disabilities ACT (ADA) Compliance

When planning where to install these devices, consider factors affecting accessibility of the button panel such as height 
from the floor, distance from obstructions, and how far a user must reach to press the buttons. For guidelines, see sections 
307 (“Protruding Objects”) and 308 (“Reach Ranges”) of the 

2010 ADA Standards for Accessible Design

 available at 

http://www.ada.gov/regs2010/2010ADAStandards/2010ADAStandards.pdf

.

Site Preparation

Extron offers an assortment of mud rings, optional UL Listed in-wall junction boxes, external wall boxes (EWBs), and surface or 
tabletop mounting boxes for use with the ACP button panels. The ACP 106 EU and ACP 106 MK are 1-gang EU and MK size 
devices.

Step 3: Removing the Plastic Faceplate, Button Panel, and Changing 
the Buttons

The plastic faceplate and buttons can be replaced. Additional buttons ship with the device and 
others can be ordered from 

www.extron.com

.

To change the buttons:

1. 

Insert the Extron removal tool (pry tool) between one side of the plastic faceplate and the 
button plate. Release the catch holding the wallplate to the metal mounting plate (see 

1

 

in the figure to the right). If necessary, use the pry tool to release the second catch on the 
opposite side.

2. 

To separate the button plate from the control plate, insert a small flat-bladed screw driver 
into one of the slots (see 

2

 in the figure at the bottom of the page).

3. 

Press the blade of the screw driver in until there is an audible 
click and the tab is pushed out of the slot.

4. 

Repeat steps 2 and 3 to release all four tabs holding the button 
plate in place.

5. 

Tilt the top of the button plate forward as it is removed to 
prevent the buttons from falling out (

3

).

VOLUME

MUTE

2

2

3

3

X

MIC

PROG

RA

M

VOLUME

MUTE

PC

MIC

PR

OGRAM

X

Extr

on

Extr

on

Insert
to line.

1

1

Содержание ACP 106 EU

Страница 1: ...m and Installation When planning to install an ACP system consider how many ACP panels to use maximum cable distance and mounting see the ACP 106 EU and ACP 106 MK product pages at www extron com for...

Страница 2: ...g accessibility of the button panel such as height from the floor distance from obstructions and how far a user must reach to press the buttons For guidelines see sections 307 Protruding Objects and 3...

Страница 3: ...e DMP Plus a PS 1220EB power inserter or an Extron 12 VDC power supply Bus ID Address DIP Switches Use these DIP switches to set the six bit binary bus address for the ACP 106 EU MK Each ACP connected...

Страница 4: ...se a power supply supplied or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the unit Utilisez toujours un...

Страница 5: ...ct the power pin to any device that is already powered by the DMP Plus or by an additional power supply 3 16 5 mm Max Figure 4 Cabling ACP Devices with a PS 1220EB Power Inserter ACP 106 EU Rear Panel...

Страница 6: ...n Single LED bicolor No power eBUS cable broken Off Off Device is receiving power and communicating correctly with the DMP Plus Lights solidly Lights green Device is receiving power but cannot communi...

Страница 7: ...here the panel will be located Take into consideration the position of wall studs and windows that could obstruct cable runs 2 Install the electrical wall box see 1 in the figure to the right by follo...

Страница 8: ...ads protruding approximately 1 8 inch 3 18 mm from the surface of the spacer 5 Rotate the metal mounting bracket as necessary to ensure that the device will be aligned correctly on the mounting surfac...