Step 5: Cable All Devices

1. 

Connect the ACP panel to the host device.

2. 

Connect ACP panels to each other if multiple panels are being used in the control system (see the wiring diagram below for 
correct wiring).

NOTES:

• 

Wire both ends of each ACP cable the same. Connectors are interchangeable between the host device and ACP 
device.

• 

Do NOT power an ACP panel from more than one power source.

3. 

Apply power to the host device after correctly cabling all devices.

Cabling

Attach cables using the diagram below as a guide. Wiring is the same for all ACP models. Connect a 4-pole captive screw 
connector to each end of the cable, wiring both ends the same. In most cases, the ACP devices are powered by the host 
DMP Plus Series device. Power is carried on the V+ pin of the ACP 106 EU/MK and other ACP devices.
Extron STP20-2/1000 or STP20-2P/100 cable is recommended for ACP device connections.

G

-S

+S

+V

Ground

+

 Signal

-

 Signal

+

12 VDC

Black

and

Drains

Green

White

Red

G

-S

+S

+V

Drain Wires

Basic ACP Connector Wiring 

ACP devices that are relatively far from the host device can be connected to an optional Extron PS 1220EB eBUS power inserter 
or an Extron 12 VDC desktop power supply as shown in the diagrams below and on the next page (see the  

ACP 106 EU/MK Specifications

 at 

www.extron.com

 for cable length to determine if additional power is recommended).

ATTENTION:

 

• 

Always use a power supply supplied or specified by Extron. Use of an unauthorized power supply voids all regulatory 
compliance certification and may cause damage to the supply and the unit. 

• 

Utilisez toujours une source d’alimentation fournie par Extron. L’utilisation d’une source d’alimentation non autorisée 
annule toute conformité réglementaire et peut endommager la source d’alimentation ainsi que l’unité.

• 

If not provided with a power supply, this product is intended to be supplied by a UL Listed power source marked 
“Class 2” or “LPS” and rated output 12 VDC, minimum 1.0 A.

• 

Si ce produit ne dispose pas de sa propre source d’alimentation électrique, il doit être alimenté par une source 
d’alimentation certifiée UL de classe 2 ou LPS et paramétré à 12 VDC et 1,0 A minimum.

• 

Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities.

• 

Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une utilisation dans les espaces d’aération 
ou dans les cavités murales.

• 

The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, 
article 725 and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently fixed to 
building structure or similar structure.

• 

Cette installation doit toujours être en accord avec les mesures qui s’applique au National Electrical Code ANSI/
NFPA 70, article 725, et au Canadian Electrical Code, partie 1, section 16. La source d’alimentation ne devra pas être 
fixée de façon permanente à une structure de bâtiment ou à une structure similaire.

Содержание ACP 106 EU

Страница 1: ...m and Installation When planning to install an ACP system consider how many ACP panels to use maximum cable distance and mounting see the ACP 106 EU and ACP 106 MK product pages at www extron com for...

Страница 2: ...g accessibility of the button panel such as height from the floor distance from obstructions and how far a user must reach to press the buttons For guidelines see sections 307 Protruding Objects and 3...

Страница 3: ...e DMP Plus a PS 1220EB power inserter or an Extron 12 VDC power supply Bus ID Address DIP Switches Use these DIP switches to set the six bit binary bus address for the ACP 106 EU MK Each ACP connected...

Страница 4: ...se a power supply supplied or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the unit Utilisez toujours un...

Страница 5: ...ct the power pin to any device that is already powered by the DMP Plus or by an additional power supply 3 16 5 mm Max Figure 4 Cabling ACP Devices with a PS 1220EB Power Inserter ACP 106 EU Rear Panel...

Страница 6: ...n Single LED bicolor No power eBUS cable broken Off Off Device is receiving power and communicating correctly with the DMP Plus Lights solidly Lights green Device is receiving power but cannot communi...

Страница 7: ...here the panel will be located Take into consideration the position of wall studs and windows that could obstruct cable runs 2 Install the electrical wall box see 1 in the figure to the right by follo...

Страница 8: ...ads protruding approximately 1 8 inch 3 18 mm from the surface of the spacer 5 Rotate the metal mounting bracket as necessary to ensure that the device will be aligned correctly on the mounting surfac...

Отзывы: