6
ACP 106 EU/MK • Setup Guide (Continued)
Step 6: Configure the System
NOTE:
For complete information on creating configuration files and operating DSP Configurator, see the host device user
guide and the DSP
Configurator Help
file.
1.
Create a new host device configuration file in DSP Configurator and create all groups, presets, and macros to be controlled
by the ACP device.
2.
Select
Tools
>
Configure ACPs
in DSP Configurator and configure the ACP button actions and panel IDs.
3.
Connect to the host device in Live mode with a TCP/IP connection and push the configuration file to the device.
Step 7: Test and Troubleshoot
1.
Verify the ACP bus ID DIP switches are set to the desired address on each unit and that there are no bus ID address conflicts
in the system.
The ACP 106 EU/MK has a rear panel LED that can be used as a diagnostic tool. Your model may have a single monochrome
LED (green) or a single bicolor LED that can light green, amber, or red (amber + green). The device status indicated by the
LED is shown in this table:
Device Status
Single LED (green)
Single LED (bicolor)
No power, eBUS cable broken.
Off
Off
Device is receiving power and communicating correctly
with the DMP Plus.
Lights solidly
Lights green
Device is receiving power but cannot communicate with
the DMP Plus.
Slow blink
Lights amber
Device is receiving power and communicating with the
DMP Plus but there is an address conflict.
Fast blink
Lights red
2.
Verify cables to and from the ACP devices are wired the same at each end.
3.
Test the system:
a.
Press the ACP device buttons and ensure the buttons light as expected and that the appropriate control actions are
triggered. Commands can be verified using DSP Configurator. DataViewer can also be used for command verification if
responses are configured.
b.
Ensure the audio levels respond correctly to the volume and mute buttons.
4.
Make adjustments to wiring, bus ID addresses, and system configuration as needed. Remember that the rear panel ports and
DIP switches are not accessible after the ACP is mounted. If needed, push a revised configuration to the ACP device through
the host device using DSP Configurator.
If you have questions during installation and setup, call the Extron S3 Sales and Technical Support Hotline or the Extron S3
Control Systems Support Hotline (1.800.633.9877).