Maximum safety
Delta-peak sensitivity: The automatic charge termination program based on the
principle of the Delta-peak voltage detection. When the battery's voltage
exceeds the threshold, the process will be terminated automatically.
SPECIAL FEATURES
Automatic charging current limit
You can set up the upper limit of the charging current when charging your NiCd or
NiMH battery; it is useful for the NiMH battery of low impedance and capacity in
the 'AUTO' charging mode.
Capacity limit
The charging capacity is always calculated as the charging current multiplied by
time. If the charging capacity exceeds the limit, the process will be terminated
automatically when you set the maximum value.
Temperature threshold*
The battery's internal chemical reaction will cause the temperature of the
battery to rise. If the temperature limit is reached, the process will be terminated.
* This function is available by connecting optional temperature probe, which is
not included in the package.
Processing time limit:
You can also limit the maximum process time to avoid any possible defect.
Data store/load
The maximum ten batteries data can be stored for users convenience. You can keep the
data pertaining to program setting of the battery of continuous charging or discharging.
Users can call out these data at any time without any special program setting.
03
Cyclic charging/discharging
1 to 5 cyclic and continuous process of charge> discharge or discharge> charge is
operable for battery refreshing and balancing to stimulate the battery’s activity.
Содержание x-605
Страница 1: ......
Страница 13: ...PROGRAM FLOW CHART Program flow chart 11 Continue on next page ...
Страница 14: ...PROGRAM FLOW CHART 12 Program flow chart ...
Страница 35: ......
Страница 36: ...Printed in China 2009 All specifications and figures are subject to change without notice C X 605 X 605 ...