CHARGING OF THE PB BATTERY
Charging of the Pb battery
Battery
type
DEC
-
Batt type
Stop
Elapsed
time
INC
+
Charge
current
Battery
voltage
DEC
Start
Enter
-
INC
+
Charged
capacity
Set up the charge current on the left and nominal voltage on the right.
Range of current is 0.1-5.0A, the voltage should match the battery being
charged. Press START/ENTER key for more than 3 seconds to start
charging.
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press START/ENTER key
again to store the parameter value you set. Press BATT TYPE/STOP key
to end the program.
25
This program is only suitable for charging Pb (lead-acid) battery with nominal voltage from 2
to 20V. Pb (lead-acid) battery is completely different from NiCd/NiMH battery. These batteries
can only deliver current lower in comparison to their capacity. The same restriction applies to
the charging process. Consequently, the optimum charge current can only be 1/10 of the
capacity. Pb battery can not be used for fast-charging, please follow the instructions provided
by the battery manufacturer.
Due to the chemistry characteristic of Pb battery, the cut off point may be difficult to dete ct
sometimes. We recommend user to use CAPACITY CUT OFF feature to protect the battery.
You can press START/ENTER key to make it blink and alter the value of parameters using INC
or DEC key, press START/ENTER key to store the value.
Charging Pb (lead-acid) battery in the charge mode
‘>3 second’