Step 9: You can begin taking measurements by clicking on points on the map that correspond to your 

current location.  There are two options for recording data under the Mode 

Mode 

Mode 

Mode section.  Single Marker

Single Marker

Single Marker

Single Marker mode 

records a single measurement point on the drawing file when you left click a point on the map.  Track Run

Track Run

Track Run

Track Run 

mode records multiple points along a straight line which are collected and plotted between your start and 

end point clicks.  Track runs are continuously drawn unless you switch back to Single Marker

Single Marker

Single Marker

Single Marker mode.  If you 

wish to delete a measurement, click on the Undo

Undo

Undo

Undo button.  For further explanations of these two modes, 

please refer to Taking Measurements

Taking Measurements

Taking Measurements

Taking Measurements in Chapter 3 

Chapter 3 

Chapter 3 

Chapter 3 –

––

– Measurement Surveys

 Measurement Surveys

 Measurement Surveys

 Measurement Surveys in the Summit WMScanner

Summit WMScanner

Summit WMScanner

Summit WMScanner User 

 User 

 User 

 User 

Manual

Manual

Manual

Manual.   

 

Step 10: If you find that you are zoomed too far in or out, click on the 

    icon.  Left click and hold the 

mouse button while the cursor is in the drawing window and move the mouse up or down in order to zoom 

in or out.  When you are done, right click in the drawing window and go to Exit

Exit

Exit

Exit.  To pan the drawing file so 

that you can take a measurement in a certain location of the map, click on the 

 icon.  Left click and hold 

the mouse button with the cursor in the drawing window.  Move the mouse in the direction you wish to pan 

to.  To exit Pan

Pan

Pan

Pan mode, right click in the drawing window and choose Exit

Exit

Exit

Exit.   

 

Step 8: When you are done taking measurements, click the Exit

Exit

Exit

Exit button. 

 

Содержание Summit WMScanner 12.0

Страница 1: ...s Table of Contents Table of Contents Recommended System Requirements 2 Installation on Win XP or Win Vista 2 WLAN Card Hardware Removal Procedure 3 Custom Driver Installation for the WLAN Client Card...

Страница 2: ...he supported cards are Netgear RangeMax Dual Band Wireless N USB a b g n Adapter WNDA3100 v1 Ubiquity SR71 USB a b g n Adapter Netgear ProSafe Dual Band a b g Wireless PC Card Model WAG511 v2 Ubiquiti...

Страница 3: ...tion executable and choose a location for storing the temporary installation files These files can be removed at a later date or kept for product repairs or reinstallations 4 Read the warnings and the...

Страница 4: ...iver The installation of the custom WLAN driver may not work correctly if the manufacturer s driver has been previously installed on your computer If the manufacturer s driver or other suitable driver...

Страница 5: ...n the driver installation process Step 5 You must accept the license agreement before installing the driver If you accept the agreement check the radio button I accept thi I accept thi I accept thi I...

Страница 6: ...7 Step 6 The wizard will begin searching for your new hardware If you receive a warning message saying that the software you are installing has not passed Windows Logo testing click Continue Anyway Co...

Страница 7: ...rt of Extreme Networks Wireless Management Suite WMS software It uses the same Serial Voucher Number as the WMS The WMS Serial Voucher Number can be found on the product label located on the outside f...

Страница 8: ...ner Loading Raster Images Raw CAD files or Formatted Drawing Files Step 1 Select the File File File File menu Open Project Floor Plan Open Project Floor Plan Open Project Floor Plan Open Project Floor...

Страница 9: ...You can still choose to scale the formatted drawing file in order to ensure that it is scaled properly Step 4 You should now see your facility in the main drawing window You are now ready to perform a...

Страница 10: ...ame the location where the measurement run log file is saved mobile receiver height and marker color Ensure that the WLAN Device WLAN Device WLAN Device WLAN Device option is selected from the Se Se S...

Страница 11: ...149 165 on the 5 GHz band If you need to change the default scan settings click the Configure Scan Settings Configure Scan Settings Configure Scan Settings Configure Scan Settings button In the Config...

Страница 12: ...e Access Points Visible Access Points Visible Access Points Visible Access Points list refresh at least 5 times before proceeding this can be seen by periodic updates to the Visible Access Points Visi...

Страница 13: ...button In the Configure Authorized List Configure Authorized List Configure Authorized List Configure Authorized List dialog window you will see that all the MAC addresses for visible APs will initial...

Страница 14: ...Measurements Taking Measurements Taking Measurements Taking Measurements in Chapter 3 Chapter 3 Chapter 3 Chapter 3 Measurement Surveys Measurement Surveys Measurement Surveys Measurement Surveys in t...

Страница 15: ...the type of heat map being displayed click on the pull down menu next to Map Map Map Map and choose from the list For an explanation of what the different heat map visualizations mean please refer to...

Страница 16: ...11b g n click on the pull down tab next to Standard Standard Standard Standard and select 802 11a 802 11a 802 11a 802 11a n n n n The Heat map visualizations for the 802 11a n standard should now app...

Страница 17: ...de at http www extremenetworks com go TACUserGuide The Extreme Networks eSupport website provides the latest information on Extreme Networks products including the latest Release Notes troubleshooting...

Отзывы: