Displaying the status of the power supplies
You can display the status of the power supplies by entering the
show chassis
command at any level of the CLI. The display shows
whether a power supply is installed in the specified power supply slot and the status of the power supply. If you are not already attached
to a terminal or a PC running terminal emulation, see
Displaying the status of the power supplies
device> show chassis
*** CES 2000 Series 2048CX ***
---POWERS ---
Power 1 ( 3I50 - AC 504W): Installed (OK)
Power 2: not present
Total power budget for system = 504 W
--- FANS ---
Metro fan tray (fan 1): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 2): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 3): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 4): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 5): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 6): Status = OK, Speed = LOW (50%)
--- TEMPERATURE READINGS ---
CPU: Board 32.50C Chip 41.6C
481XG PPCR1: Board 32.50C Chip 43.31C
481XG PPCR2: Board 29.50C Chip 41.93C
2X10G PPCR: Board 33.0C Chip 41.68C
Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds
Base MAC Address = 001b.ed39.0300
CES 2000 Series 2048CX>
Syntax:
show chassis
10-Gigabit Ethernet module installation or
replacement
The 2-port 10-Gigabit Ethernet modules may optionally be installed or replaced in the field on the CES 2000 Series 2024C, CES
2000 Series 2024F, CER 2000 Series 2024C, CER 2000 Series 2024F units. You can order the Extreme Networks device with a 2
x10-Gigabit module installed at the factory, or you can upgrade your device later.
This section provides the steps for installing, removing, and replacing the 10-Gigabit Ethernet module. You will need the following tools
to perform these procedures:
•
#2 Phillips-head screwdriver
•
Electrostatic Discharge (ESD) kit
DANGER
For safety reasons, the ESD wrist strap should contain a series 1 megaohm resistor.
Removing a 2 x10-Gigabit Ethernet module
Follow the procedure given below while removing a 2 x10-Gigabit Ethernet module.
1. Power off the Extreme Networks device.
2. Use a #2 Phillips-head screwdriver to loosen the screws on the 2 x10-Gigabit module.
3. Remove the 2 x10-Gigabit module.
4. Place the 2 x10-Gigabit module in an anti-static bag for storage.
5. If you are removing the module without replacing it, install the blank faceplate in the front panel.
10-Gigabit Ethernet module installation or replacement
ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide
86
9035631-01
Содержание ExtremeRouting CER 2000 Series
Страница 40: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 40 9035631 01...
Страница 68: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 68 9035631 01...
Страница 92: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 92 9035631 01...
Страница 98: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 98 9035631 01...