Description and Operating Instructions
Industrial ETHERNET F/O /Twisted
Pair/Coax Hub for ISO/DIN Rail (Navy)

The rail hub RH1-CX+ supports a fast and
reasonable network expansion. It enables
the universal media transition between
10BASE-FL (fiber optic cable, F/O), 10BASE-
T (twisted pair cable, TP) and 10BASE-2
(coax cable).

The rail hubs are equipped with
– one F/O interface (ST connector)
– two TP interfaces (RJ45 sockets)
– one coax interface (BNC socket).

You can connect
– one data terminal equipment or further

segment via F/O

– up to two data terminal equipments or

further twisted pair segments via twisted
pair

– one data terminal equipment or one furt-

her coax segment via coax.

For startup procedure just fit the rail hub
on an ISO/DIN rail, without any further con-
figuration time. The V.24 voltage is supplied
via the terminal block and can be feed in
redundantly.

The terminal block contains an integrated
indicator contact, receiving error and war-
ning messages of the rail hub which are
defined as digital signals. These signals e.g.
can be utilized as process messages by a
programmable logic control (PLC). The indi-
cator contact becomes active as soon as
disturbances appear in the rail hubs, that is
when a power supply should fail or at least
one port (TP, FL) reports a faulty link status
or has auto partitioned.

For diagnosis there are LEDs available
which indicate link status, segmentation,
power and received data.

The module conforms to the specifications
of ISO/IEC standard 8802-3.

You will find a detailed description for con-
struction of a local area network on network
planning and installation in the “Ethernet
manual“ (Order no. 943 320-011).

RH1-CX+

Order No. 

943 701-002

2

3

1

4

FAULT

1

DA/STAT

2

3

P

0 1

LA1
LA2
LA3

RH1-CX+

i

2

+24V

FAUL

T

+24V*

1

4

C

Port 1 … Port 3

DIL Switch Settings:

Made in Germany

LA1 … LA3

Link Alarm

0

Disabled

1

Enabled

RH1-CX+

!7

Port 1 … Port 3

DIL Switch Settings:

Rail Hub (Navy)
RH1-CX+

Made in Germany

LA1 … LA3

Link Alarm

0

Disabled

1

Enabled

xxxxxx

Содержание RH1-CX+

Страница 1: ... an integrated indicator contact receiving error and war ning messages of the rail hub which are defined as digital signals These signals e g can be utilized as process messages by a programmable logic control PLC The indi cator contact becomes active as soon as disturbances appear in the rail hubs that is when a power supply should fail or at least one port TP FL reports a faulty link status or h...

Страница 2: ...og and technical description and only in conjunction with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Safety Guidelines Power Supply Switch the basic devices on only when the case is close...

Страница 3: ... operated Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions z Warning Failure to observe the information given in the warnings could result in serious injury and or major damage Only personnel that have received appropriate training should operate this device or work in its immediate vicinity The personnel must be fully...

Страница 4: ...ort circuit or interrupt using idle signals during frame pauses in accordance with IEEE standard 802 3 10BASE T The RH1 CX does not transmit any data in a TP segment from which it does not receive an idle signals Note A non occupied interface is assessed as a line interrupt The TP line to terminal equipment which is switched off is likewise assessed as a line interrupt as the de energised transcei...

Страница 5: ...l switch RH1 CX automaton trans ceiver PLC twisted pair lines DTE F O line coax line TP interface Two 8pole shielded RJ45 sockets enable two independent TP segments complying with 10BASE T to be connected The hou sings of the sockets are galvanically con nected to the front panel Pin configuration of the RJ45 socket MDI X TD Pin 3 TD Pin 6 RD Pin 1 RD Pin 2 remaining pins not configured Fig 2 Pin ...

Страница 6: ...esses of our contract partners on the Internet http www hirschmann de Our support line is also at your disposal Tel 49 1805 14 1538 Fax 49 7127 14 1551 Answers to Frequently Asked Questions can be found on the Hirschmann internet site www hirschmann de The FAQs are located under Service in the Automation and Network Solutions section www hicomcenter com gives you an up to date overview of training...

Страница 7: ...on all ports Propagation equivalent 240 m 787 ft Variability value 3 BT F O port Optical output power Gradient fiber 50 125 µm average min 22 0 dBm max 16 0 dBm Gradient fiber 62 5 125 µm average min 19 0 dBm max 12 0 dBm Optical input power min 33 0 dBm TP line length Length of a twisted pair segment max 100 m 328 ft Coax line length Length of a coax segment max 185 m 607 ft F O line length examp...

Страница 8: ...and Network Solutions Stuttgarter Straße 45 51 D 72654 Neckartenzlingen Germany Tel 49 1805 14 1538 Fax 49 7127 14 1551 E Mail ans support hirschmann de Internet http www hirschmann com Printed in Germany Subject to alterations 039628002020604000 ...

Отзывы: