Stability

Vibration

IEC 60068-2-6 Test FC, testing level in line with IEC 61131-2 E2 CDV
Germanischer Lloyd Guidelines for the Performance of Type Tests Part 1

Shock

IEC 60068-2-27 Test Ea, testing level in line with IEC 61131-2 E2 CDV

Interfaces

1 port complying with 10BASE-FL with ST connecors

2 ports complying with 10BASE-T with RJ45 connectors (shielded)
1 port complying with 10BASE-2 with BNC socket
1 x 5 pole mountable terminal block

Displays

P1, P2: power
FAULT: indicator contact indicates error
DA/STAT1 to DA/STAT 3: data, link status per port, segmentation (TP/FL ports)
DA/STAT 4: data, segmentation (BNC port)

Controls

3-pin DIP switch 

LA1 to LA3

– Suppress linkstatus message on port-by-port basis

Network size

Transition (all ports)

Propagation equivalent

240 m (787 ft)

Variability value

3 BT

F/O port

Optical output power

Gradient fiber 50/125 µm (average)

min. -22.0 dBm

max. -16.0 dBm

Gradient fiber 62,5/125 µm (average)

min. -19.0 dBm

max. -12.0 dBm

Optical input power

min. -33.0 dBm

TP line length

Length of a twisted pair segment

max. 100 m (328 ft)

Coax line length

Length of a coax segment

max. 185 m (607 ft)

F/O line length (example)

50/125 µm fiber

max. 2.600 m (8,530 ft)

62,5/125 µm fiber

max. 3.100 m (10,170 ft)

Scope of delivery

RH1-CX+ Twisted Pair Industrial Hub for ISO/DIN Rail (Navy) incl.

terminal block for supply voltage
description and operating instructions

Order number

RH1-CX+ – Twisted Pair Industrial Hub 
for ISO/DIN Rail (Navy)

943 071-002

Accessories

ETHERNET manual

943 320-011

Manual
Basics Industrial ETHERNET and TCP/IP

280 720-834

Rail Power Supply RPS 30

943 662-003

Rail Power Supply RPS 60

943 662-001

Rail Power Supply RPS 120

943 662-011

Содержание RH1-CX+

Страница 1: ... an integrated indicator contact receiving error and war ning messages of the rail hub which are defined as digital signals These signals e g can be utilized as process messages by a programmable logic control PLC The indi cator contact becomes active as soon as disturbances appear in the rail hubs that is when a power supply should fail or at least one port TP FL reports a faulty link status or h...

Страница 2: ...og and technical description and only in conjunction with external devices and components recommen ded or approved by Hirschmann The product can only be operated correctly and safely if it is transpor ted stored installed and assembled properly and correctly Furthermore it must be operated and serviced carefully Safety Guidelines Power Supply Switch the basic devices on only when the case is close...

Страница 3: ... operated Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions z Warning Failure to observe the information given in the warnings could result in serious injury and or major damage Only personnel that have received appropriate training should operate this device or work in its immediate vicinity The personnel must be fully...

Страница 4: ...ort circuit or interrupt using idle signals during frame pauses in accordance with IEEE standard 802 3 10BASE T The RH1 CX does not transmit any data in a TP segment from which it does not receive an idle signals Note A non occupied interface is assessed as a line interrupt The TP line to terminal equipment which is switched off is likewise assessed as a line interrupt as the de energised transcei...

Страница 5: ...l switch RH1 CX automaton trans ceiver PLC twisted pair lines DTE F O line coax line TP interface Two 8pole shielded RJ45 sockets enable two independent TP segments complying with 10BASE T to be connected The hou sings of the sockets are galvanically con nected to the front panel Pin configuration of the RJ45 socket MDI X TD Pin 3 TD Pin 6 RD Pin 1 RD Pin 2 remaining pins not configured Fig 2 Pin ...

Страница 6: ...esses of our contract partners on the Internet http www hirschmann de Our support line is also at your disposal Tel 49 1805 14 1538 Fax 49 7127 14 1551 Answers to Frequently Asked Questions can be found on the Hirschmann internet site www hirschmann de The FAQs are located under Service in the Automation and Network Solutions section www hicomcenter com gives you an up to date overview of training...

Страница 7: ...on all ports Propagation equivalent 240 m 787 ft Variability value 3 BT F O port Optical output power Gradient fiber 50 125 µm average min 22 0 dBm max 16 0 dBm Gradient fiber 62 5 125 µm average min 19 0 dBm max 12 0 dBm Optical input power min 33 0 dBm TP line length Length of a twisted pair segment max 100 m 328 ft Coax line length Length of a coax segment max 185 m 607 ft F O line length examp...

Страница 8: ...and Network Solutions Stuttgarter Straße 45 51 D 72654 Neckartenzlingen Germany Tel 49 1805 14 1538 Fax 49 7127 14 1551 E Mail ans support hirschmann de Internet http www hirschmann com Printed in Germany Subject to alterations 039628002020604000 ...

Отзывы: