NOTE

ExtremeSwitching CES-4X-RT/ExtremeRouting CER-4X-RT supports the XNI-CE-2000-FAN pre-installed or as a spare. All
other models support the NI-CE-2000-FAN.

The fans in the devices include six four-speed fans that operate at low speed, medium speed, medium-high speed, and high speed
based on the ambient temperature and configured or default temperature thresholds. All fans operate simultaneously at the same speed.
If a single fan fails within the assembly, the fan tray should be replaced. The fan tray is hot swappable and the mean time to recover
(MTTR) is one minute.

The system uses a default or configured temperature threshold associated with it to determine at which speed the fan should operate.

Hardware features

ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide

34

9035631-01

Содержание ExtremeRouting CER 2000 Series

Страница 1: ...HARDWARE INSTALLATION GUIDE ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 9035631 01 November 2018...

Страница 2: ...nt are the property of their respective owners and may be trademarks or registered trademarks of their respective companies owners For additional information on Extreme Networks trademarks please see...

Страница 3: ...es 20 Upgrade applications 20 Hardware features 21 CES 2000 Series 2024C 4X 21 CES 2000 Series 2024F 4X 21 CES 2000 Series 2024C 22 CES 2000 Series 2024F 22 CES 2000 Series 2048C 22 CES 2000 Series 20...

Страница 4: ...51 Installing the device in a rack 51 System power 56 Powering on the system 57 Operation verification 57 Verifying proper operation 57 Observing the power status LEDs 58 PC or terminal attachment 59...

Страница 5: ...Fiber optic connector cleaning 91 Regulatory Statements 93 BSMI statement Taiwan 93 Canadian requirements 93 China CC statement 94 Europe and Australia CISPR 22 Class A Warning 94 FCC warning US only...

Страница 6: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 6 9035631 01...

Страница 7: ...interrupted or the device might reboot CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware firmware software or data DANGER A Dan...

Страница 8: ...enter the entire command at the prompt without the backslash Documentation and Training To find Extreme Networks product guides visit our documentation pages at Current Product Documentation www extre...

Страница 9: ...urned the device before or if this is a recurring problem Any related RMA Return Material Authorization numbers Subscribing to Service Notifications You can subscribe to email notifications for produc...

Страница 10: ...e part number and as much detail as possible including the topic heading and page number if applicable as well as your suggestions for improvement Providing Feedback to Us ExtremeSwitching CES 2000 Se...

Страница 11: ...t supported Refer to the End of Sale and End of Support page under https www extremenetworks com support end of sale and end of support products for additional information The following hardware platf...

Страница 12: ...net Explorer Mozilla Corporation Mozilla Firefox Oracle Corporation Java Runtime Environment What s new in this document NOTE The NetIron 6 3 00 release the image files and the documentation is no lon...

Страница 13: ...and education or research can be addressed with the CES 2000 Series and CER 2000 Series devices This guide includes procedures for installing the hardware and configuring essential basic parameters su...

Страница 14: ...S 2000 Series 2024C 4X FIGURE 2 CES 2000 Series 2024F 4X FIGURE 3 CES 2000 Series 2024C Introduction ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 14...

Страница 15: ...CES 2000 Series 2024F FIGURE 5 CES 2000 Series 2048C FIGURE 6 CES 2000 Series 2048F Introduction ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 903563...

Страница 16: ...2x10G uplink slot CER 2000 Series RT 2024C accommodates 24 port 10 100 1000 Copper RJ45 model with 4 combination 100 1000 Hybrid Fiber HF ports and an optional field upgradeable 2x10G uplink slot This...

Страница 17: ...G XFP uplink ports CER 2000 Series RT2048CX accommodates 48 port 10 100 1000 RJ45 model with 2x10G XFP uplink ports This device has the ability to simultaneously store up to 1 5 million IPv4 routes an...

Страница 18: ...CER 2000 Series 2024F FIGURE 13 CER 2000 Series 2048C FIGURE 14 CER 2000 Series 2048F Introduction ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 18 9...

Страница 19: ...P networks mobile backhaul networks data centers large enterprises government networks and education or research FIGURE 17 CES 2000 Series switch The CER 2000 Series is a compact 1 RU IP MPLS and mult...

Страница 20: ...up to 1 5 million IPv4 routes and up to 256 000 IPv6 routes All ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series devices can be upgraded to premium packages Upgrade applications Yo...

Страница 21: ...d Console one 10 100 1000 MbE RJ45 out of band management port one resilient six unit fan tray and two AC power supply bays for 1 1 redundancy with one 500W AC power supply included FIGURE 19 CES 2000...

Страница 22: ...rts one module slot for an optional field upgradable 2 port 10 GbE XFP module one DB9 serial management interface port labeled Console one 10 100 1000 MbE RJ45 out of band management port one resilien...

Страница 23: ...AC power supply included FIGURE 24 CES 2000 Series 2048CX device 1 10 GbE XFP ports 2 Forty eight 10 100 1000 MbE RJ45 ports CES 2000 Series 2048F CES 2000 Series 2048F Fiber has forty eight 100 1000...

Страница 24: ...bE RJ45 out of band management port one resilient six unit fan tray and two AC power supply bays for 1 1 redundancy with one 500W AC power supply included The CER 2000 Series RT 2024C router has more...

Страница 25: ...ur combination 10 100 1000 MbE RJ45 ports with support for optional 10Gbe XFP ports 2 Twenty four 100 1000 MbE SFP ports CER 2000 Series 2048C CER 2000 Series 2048C Copper router has forty eight 10 10...

Страница 26: ...Series 2048CX device 1 10 GbE XFP ports 2 Forty eight 10 100 1000 MbE RJ45 ports CER 2000 Series 2048F CER 2000 Series 2048F Fiber has forty eight 100 1000 MbE SFP ports one DB9 serial management inte...

Страница 27: ...l features Serial Management Interface the port labeled Console 10 100 1000 ports with RJ 45 copper connectors 100 1000 Hybrid Fiber HF ports 100 1000 ports with mini GBIC slots for SFP MSA compliant...

Страница 28: ...eceived on the fiber port 10 Gbps Port LEDs on devices with four 10 Gbps ports Top Left hand port On The port is connected Off No fiber port connection exists Blinking Traffic is being transmitted and...

Страница 29: ...0 Gigabit Small Form Factor Pluggable XFP MSA compliant transceivers Supported optics 100 1000 Ethernet Ports The Ethernet Interface module contains 24 or 48 physical ports through which you can conne...

Страница 30: ...owing 10 Gigabit optics are available from device TABLE 6 MSA compliant Optics for the 10 GbE Ethernet interface module Part number Description Devices with up to two 10GbE ports XFP 10G XFP SR 850nm...

Страница 31: ...S 2000 Series 2048FX CER 2000 Series 2048CX and CER 2000 Series 2048FX models only CES 2000 Series 2024x and CER 2000 Series 2024x devices with 24 ports have 2 optional 10 G ports Ports 1 1 1 24 Port...

Страница 32: ...supply provides enough power for the entire system The following sections provide further details about the power supplies for the devices Power status LEDs are listed in Power supplies Hardware speci...

Страница 33: ...ower grid connected to the power supply Cooling system and fans This section describes the fans in the devices with 6 fans Cooling system and fans shows the cooling fans FIGURE 35 Cooling Fans 1 Six c...

Страница 34: ...e and configured or default temperature thresholds All fans operate simultaneously at the same speed If a single fan fails within the assembly the fan tray should be replaced The fan tray is hot swapp...

Страница 35: ...d into the Privileged level of the EXEC mode NOTE You can assign passwords using the Extreme Network Advisor if an Enable password for a Super User is already configured on the device You can set the...

Страница 36: ...ment are forwarded TABLE 7 Assigning IP addresses Interface Associated physical port Out of band In band Management interface Ethernet 10 100 1000 port on active management module Out of band Any inte...

Страница 37: ...rase the configuration on a configured system enter the write memory command to save the running configuration to the startup config file 3 Access the configuration level of the CLI by entering the fo...

Страница 38: ...erminal Syntax no ip address ip addrip mask secondary or Syntax no ip address ip addr mask bits secondary Use the secondary parameter if you have already configured an IP address within the same sub n...

Страница 39: ...istribute directly connected or static routes associated with the interface module ports but not those associated with the management port To display configuration information and statistics about the...

Страница 40: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 40 9035631 01...

Страница 41: ...ter A management station such as a PC running a terminal emulation application A straight through EIA TIA DB 9 serial cable F F The serial cable can be ordered separately from Extreme Networks If you...

Страница 42: ...7 6 Attach a terminal or PC to the device This will enable you to configure the device through the Command Line Interface CLI PC or terminal attachment on page 59 7 No default password is assigned to...

Страница 43: ...Ensure that the device does not overload the power circuits wiring and over current protection To determine the possibility of overloading the supply circuits add the ampere amp ratings of all devices...

Страница 44: ...restricted access area is a location where access can be gained only by trained service personnel through the use of a special tool lock and key or other means of security and is controlled by the aut...

Страница 45: ...c Code apply The device must be installed in a restricted access location either a Central Office or customer premises equipment location Redundant power supply installation The Extreme Networks devic...

Страница 46: ...power supplies in the ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series devices Redundant power supply installation ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Seri...

Страница 47: ...power supply and insert the power supply into the empty power supply slot Press until the supply is completely in the slot so that the connectors on the back of the supply are fully engaged with the...

Страница 48: ...e a star washer to ensure an NEBS compliant connection Installing a DC power supply DANGER Before beginning the installation see the precautions in Power precautions Use the following procedures for D...

Страница 49: ...pply into the empty power supply slot Press until the supply is completely in the slot so that the connectors on the back of the supply are fully engaged with the pins on the power backplane Installin...

Страница 50: ...pply in place Installing a DC power supply FIGURE 40 DC power supply screws 1 Chassis attachment screws 2 Assembly screws Redundant power supply installation ExtremeSwitching CES 2000 Series and Extre...

Страница 51: ...two hole ground lug a minimum of 20 inch pounds of torque is required to be applied to the mounting hardware used to attach the ground lug Use a star washer to ensure an NEBS compliant connection Devi...

Страница 52: ...FIGURE 41 Front rack mount position Device installation ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 52 9035631 01...

Страница 53: ...ch offset rack mount position FIGURE 42 5 Inch offset rack mount position Device installation ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 9035631 01...

Страница 54: ...Mid rack mount position FIGURE 43 Mid rack mount position Device installation ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 54 9035631 01...

Страница 55: ...Reverse rack mount position FIGURE 44 Reverse rack mount position Device installation ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 9035631 01 55...

Страница 56: ...g network or an isolated bonding network 3 Proceed to System power on page 56 You will need the following tools for installation 2 Phillips head screwdriver Four 10 24 screws or as specified by rack t...

Страница 57: ...ORE Issue 5 and require isolation from the exposed OSP cabling The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring NOTE Befo...

Страница 58: ...connected or a fault is detected Green Power supply 1 is installed and is functioning normally AC PS2 labeled P2 Right side of front panel Off Power supply 2 is not installed or is not providing powe...

Страница 59: ...led The software regularly polls the hardware for power status information You can display the status information from any management session In addition the software automatically generates a Syslog...

Страница 60: ...formation refer to the Extreme NetIron Management Configuration Guide If you do not see one of these prompts follow the instructions given below 3 Make sure the cable is securely connected to your PC...

Страница 61: ...anagement port s IP address The commands in the CLI are organized into the following levels User EXEC Lets you display information and perform basic tasks such as pings and traceroutes Privileged EXEC...

Страница 62: ...vity default vlan id enable enable acl counter end exit More next page Space next line Return key quit Control c The software provides the following scrolling options Press the Space bar to display th...

Страница 63: ...egular expression consisting of a single character or string of characters You can use special characters to construct complex regular expressions Refer to Using special characters in regular expressi...

Страница 64: ...from this prompt For example device append Append one file to another attrib Change file attribute boot Boot system from bootp tftp server flash image cd Change current working directory chdir Change...

Страница 65: ...HOIS lookup write Write running configuration to flash or terminal As with the commands for filtering output from show commands the search string is a regular expression consisting of a single charact...

Страница 66: ...you to use it as part of a regular expression A caret when not used within brackets matches on the beginning of an input string For example the following regular expression matches output that begins...

Страница 67: ...is present See the example above A vertical bar separates two alternative values or sets of values The output can match one or the other value For example the following regular expression matches out...

Страница 68: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 68 9035631 01...

Страница 69: ...Table 14 provides the maximum power calculations TABLE 14 Maximum power calculations at 100 240 VAC with two PSUs Devices Watts BTUs per hour CES 2000 Series 2024C 4X 200 682 CES 2000 Series 2024C 4X...

Страница 70: ...m 17 44 in44 3 cm 17 30 in43 9 cm 20 95 CES 2000 Series 2024C 1 RU1 7 inches4 4 cm 17 44 in44 3 cm 17 64 in44 8 cm 15 5 CES 2000 Series 2024C with 2x10G uplink installed 1 RU1 7 inches4 4 cm 17 44 in4...

Страница 71: ...17 5 CER 2000 Series 2048F 1 RU1 7 inches4 4 cm 17 44 in44 3 cm 17 3 in43 9 cm 16 5 CER 2000 Series 2048FX 1 RU1 7 inches4 4 cm 17 44 in44 3 cm 17 3 in43 9 cm 17 5 Operating environment The following...

Страница 72: ...s console port serial connector Device s management port RJ 45 unshielded twisted pair UTP connector DANGER The intra building port or ports of the equipment or subassembly is suitable for connection...

Страница 73: ...le options between the Extreme Networks device and a PC or terminal are shown in Figure 47 NOTE As indicated in Console port pin assignments and Figure 47 some of the wires should not be connected If...

Страница 74: ...3 RD 4 Not used 10BaseT CMT 100BaseTX 5 Not used 10BaseT CMT 100BaseTX 6 RD 7 Not used 10BaseT CMT 100BaseTX 8 Not used 10BaseT CMT 100BaseTX Port specifications ExtremeSwitching CES 2000 Series and...

Страница 75: ...CER 2000 Series 2024C CER 2000 Series 2024F models Power supply replacement You can replace a power supply while the Extreme Networks device is powered on and running The power supplies are located in...

Страница 76: ...fan tray fan 4 Status OK Speed MED 75 Metro fan tray fan 5 Status OK Speed MED 75 Metro fan tray fan 6 Status OK Speed MED 75 TEMPERATURE READINGS CPU Ambience 35 50C Chip 39 68C 24X1G PPCR Ambience...

Страница 77: ...Networks recommends that you disconnect the power supply from AC power before installing or removing the supply CAUTION Changes or modifications made to this device that are not expressly approved by...

Страница 78: ...top left and bottom right hand corner of the power supply FIGURE 49 Power supply screw location 1 Power supply locking screws Power supply replacement ExtremeSwitching CES 2000 Series and ExtremeRouti...

Страница 79: ...cover plate over the empty power supply Refer to Installing the AC power supply on page 79 for details Installing the AC power supply Perform the following steps to install an AC power supply 1 Remov...

Страница 80: ...upply upside down 4 Tighten the two power supply locking screws located at the top left and bottom right hand corner of the power supply 5 Connect the power cord to the power supply Removing the DC po...

Страница 81: ...f Required tools FIGURE 53 The DC wiring assembly 1 Wire tightening screws 2 Assembly screws 5 Pull the power supply outward once the screws have been unscrewed This will disconnect the power supply f...

Страница 82: ...If necessary remove the power supply locking screws located in the upper left and the bottom right of the device 2 If the empty power supply bay has a cover plate remove the two screws near the edges...

Страница 83: ...supply into the empty power supply slot Press until the supply is completely in the slot so that the connectors on the back of the supply are fully engaged with the pins on the power backplane CAUTIO...

Страница 84: ...te bonding when attaching the provided Panduit LCD6 10AF two hole ground lug a minimum of 20 PSI of torque is required to be applied to the mounting hardware used to attach the ground lug Use a star w...

Страница 85: ...ed PS1 labeled P1 Off Power supply 1 is not installed or is not providing power Amber Power supply 1 is installed but not connected or a fault is detected Green Steady Power supply 1 is installed and...

Страница 86: ...chassis 10 Gigabit Ethernet module installation or replacement The 2 port 10 Gigabit Ethernet modules may optionally be installed or replaced in the field on the CES 2000 Series 2024C CES 2000 Series...

Страница 87: ...dium speed medium high speed and high speed based on the ambient temperature and configured or default temperature thresholds All fans operate simultaneously at the same speed If a single fan fails wi...

Страница 88: ...ion about the following tasks Removing a copper or fiber optic module Installing a new copper or fiber optic module Cabling a fiber optic module Removing a Copper or fiber optic module You can remove...

Страница 89: ...bail latch is enclosed in a black sleeve and on 1000BaseLX ports the bail latch is enclosed in a blue sleeve 1 Bail latch NOTE The bail latch may be attached to either the top or the bottom of the mi...

Страница 90: ...operly DANGER The intra building port or ports of the equipment or subassembly is suitable for connection to intra building or unexposed wiring or cabling only The intra building port or ports of the...

Страница 91: ...onnection between the fiber optic module SFP mini GBIC SFP or XFP and the fiber cable connectors Extreme strongly recommends cleaning both connectors each time you disconnect and reconnect them In par...

Страница 92: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 92 9035631 01...

Страница 93: ...BSMI statement Taiwan Warning This is Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Canadian requ...

Страница 94: ...lass A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures China CC statement ExtremeSwitching CES 2000 Series...

Страница 95: ...nformation regulation 3 GPSGV the highest sound pressure level value is 60 0 dB A in accordance with EN ISO 7779 Maschinenl rminformations Verordnung 3 GPSGV der h chste Schalldruckpegel betr gt 60 0...

Страница 96: ...da Class A AS NZ 55022 Australia Class A VCCI Japan Class A EN 61000 3 2 EN 61000 3 3 EN 61000 6 1 Regulatory compliance safety CAN CSA C22 2 No 60950 UL 60950 EN 60825 Safety of Laser Products EN 609...

Страница 97: ...n and Restriction of Chemicals EU REACH Section 1502 of the Dodd Frank Wall Street Reform and Consumer Protection Act of 2010 U S Conflict Minerals 30 2011 TT BCT Vietnam circular SJ T 11363 2006 Requ...

Страница 98: ...ExtremeSwitching CES 2000 Series and ExtremeRouting CER 2000 Series Hardware Installation Guide 98 9035631 01...

Страница 99: ...gebung mit einer Umgebungsbetriebstemperatur von ber 40 C 104 F installiert werden MISE EN GARDE N installez pas le dispositif dans un environnement o la temp rature d exploitation ambiante risque de...

Страница 100: ...configuraci n de inicio para sistemas nuevos solamente Si usted introduce este comando en un sistema que ya ha configurado el comando borrar la configuraci n Si usted borra accidentalmente la configur...

Страница 101: ...gang hat Dieser Zugang wird von f r den Bereich zust ndigen Personen berwacht MISE EN GARDE Tous les quipements dot s de sources d alimentation C C sont destin s tre install s uniquement dans des zone...

Страница 102: ...ten f hren MISE EN GARDE L alimentation est con u exclusivement pour une utilisation avec les quipements ExtremeSwitching CES s rie et ExtremeRouting CER s rie L alimentation produit un pouvoir tendu...

Страница 103: ...ved crimped connector provided with the chassis attached to one end with the other end attached to building ground The connector must be crimped with the proper tool allowing it to be connected to bot...

Страница 104: ...on ues pour supporter le poids du ch ssis PRECAUCI N Para prevenir da os al chasis y a los componentes nunca intente levantar el chasis usando las asas de la fuente de alimentaci n o del ventilador Ta...

Страница 105: ...sitif PELIGRO Para desconectar completamente la corriente del instrumento desconecte el cord n de corriente de todas las fuentes de corriente DANGER If the installation requires a different power cord...

Страница 106: ...n las politicas y regulaciones locales DANGER Make sure that the power source circuits are properly grounded then use the power cord supplied with the device to connect it to the power source GEFAHR...

Страница 107: ...ELIGRO Los puertos del equipo o del sistema secundario situados en el interior de un edificio nicamente podr n conectarse a instalaciones el ctricas o cableados que se encuentren dentro del edificio o...

Страница 108: ...verwenden Laser der Klasse 1 DANGER Toutes les interfaces en fibre optique utilisent des lasers de classe 1 PELIGRO Todas las interfaces de fibra ptica utilizan l ser de clase 1 Danger Notices Extreme...

Отзывы: