21
ENGLISH
operatIon and loGIC
IGnItIon
Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition
phase. after ignition and having reached the control temperature, the stove interrupts the ignition phase and passes to sTarTiNg.
preparatIon
During the start-up phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and pass on to wOrK.
work
During the work phase, the stove reaches the set power set; see following item.
set power
set the operating power from 1 to 5 (using keys 2 and 3).
Power 1 = minimum level - Power 5 = maximum level.
set h2o
set the boiler temperature from 65 to 80°C (using keys 4 and 5).
pump operatIon
The pump activates water circulation when the t° of the water inside the stove reaches approx. 60°C. as the pump always functions above 60°,
it is recommended to keep a heating area open at all times to allow for uniform operation, preventing blocks due to overheating. Normally
this area is defined as the “safety zone”.
set thermostat
it is possible to activate/deactivate front ventilation and check the room temperature by means of the room temperature probe (integrated
in the
product). (see the chapter "ventilation" on the following pages.)
Blow
During the working phase, the stove has an internal timer, which after a pre-set period of time cleans the burn pot.
This phase is shown on the display, it lowers the stove power level and increases the flue gas exhaust motor for a programmed period of time.
when the cleaning phase is finished, the stove will re-start automatically and continue the working phase, returning to the selected power
level.
modulatIon and h-off
as the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum power. if the
temperature increases beyond the set point, it will automatically switch off indicating
H-oFF
, and will automatically go back on when the
temperature drops below the set point.
swItCh-off
Press key 1 for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-off phase, blocking the supply of pellets.
the flue gas exhaust motor and the hot air flow motor will remain on until the stove temperature has dropped below the default
parameters.
re-IGnItIon
The stove can only be re-ignited automatically or manually when the cooling cycle conditions and the preset timer have been satisfied.
do not use any InflammaBle lIQuIds for IGnItIon!
do not allow the BaG of pellets to Come Into ContaCt wIth the BoIlInG hot stove durInG the
fIllInG phase! In the event of ContInued faIlure to lIGht, ContaCt an authorIsed teChnICIan.
all Components applIed to the Burn pot, supplIed wIth the applIanCe,
whICh Can Be seen In the drawInG to the sIde, must always Be Installed
durInG use.
removal wIll CompromIse the safety of the produCt and result In
the ImmedIate nullIfICatIon of the warranty perIod.
In the event of wear or deterIoratIon, ask the after-sales servICe
to replaCe the parts (replaCement does not fall wIthIn the produCt
warranty as the part Is suBJeCt to wear)