ENGLISH
settings
•
Date-tiMe
•
language
•
Degrees
See chapter: SettingS for firSt uSe
DiSPLAY
This menu allows you to adjust the brightness of the display. The possible values go from OFF, 1 to 20. if OFF, the display backlight is at the
maximum intensity and goes out after a 60 second delay.
The backlight comes back on when a key is pressed or if an alarm is generated.
CONTrOls prOCeDUre
press 6.
press 3 until
SETTingS
appears and confirm by pressing 6.
Keep pressing 3 until
DiSPLAY
appears and confirm by pressing 6.
Use keys 4 -5 to set the desired intensity.
press 6 to confirm or 1 to return to the previous menus to the initial state.
STAnD - BY
if enabled, the
STAnD-BY
function is used to switch off the machine from the additional thermostat
CONTrOls prOCeDUre
press 6.
press 3 until
SETTingS
appears and confirm by pressing 6.
Keep pressing 3 until
STAnD-BY
appears and confirm by pressing 6.
Use keys 4-5 to enable (
on
) / disable (
oFF
).
press 6 to confirm or 1 to return to the previous menus to the initial state.
J
For corrEcT oPErATion, SET THE SET THErmoSTAT To Low-TA.
> SEE cHAPTEr on THE ADDiTionAL THErmoSTAT SETTingS
stanD-by funCtion on
if the sTaND-By function is active (ON), if the room temperature exceeds the value of the
SET THErmoSTAT
+
DELTA T oFF
, then the stove
will switch off after a preset delay, displaying
STAnD-BY
.
When the room temperature is lower than the
SET THErmoSTAT
-
DELTA T
and after a possible cooling time, the stove switches back on.
stanD-by funCtion off (faCtory setting)
if the sTaND-By function is not active (OFF ), if the stove exceeds the set room temperature it will switch to the minimum value, modulating
and displaying
moDULATion
. When the room temperature is lower than the
SET THErmoSTAT
the stove goes back to operating at the set
power, displaying
work
.
operation with aDDitional therMostat (optional)
stanD-by funCtion off
(FaCTOry seTTiNg)
if the sTaND-By function is not active (OFF ), if the stove exceeds the room temperature set on the additional thermostat (contact open) it will
switch to the minimum value, displaying mODUlaTiON. When the room temperature is lower than the value set on the additional thermostat
(contact closed), the stove goes back to operating at the set power, displaying WOrK.
stanD-by funCtion on
When the sTaND-By function is active (ON), when the room temperature set on the additional thermostat has been reached (contact open),
the stove will switch off after a preset delay, displaying
STAnD-BY
.
When the room temperature is lower than the value set on the additional thermostat (contact closed) and after a possible cooling time, the
stove switches back on.