Congratulations on your purchase of the Extech RC200 RC Tweezers Multimeter This meter, using the 
tweezers adaptor, measures SMD capacitors, resistors, diodes and continuity test. With the test lead 
adaptor, it measures AC/DC Voltage. Proper use and care of this meter will provide many years of 
reliable service. 

Safety 

INTERNATIONAL ELECTRICAL SYMBOLS

 

 

 

Caution !  Refer to the explanation in this Manual 

 

 

Caution !  Risk of electric shock 

 

 Earth 

(Ground) 

 

 

Double Insulation or Reinforced insulation 

 

This meter has been designed for safe use, but must be operated with caution. The rules listed 
below must be carefully followed for safe operation. 
1. 

NEVER

 measure voltage with the Tweezer adaptor installed. 

2. 

NEVER

 apply voltage or current to the meter that exceeds the specified maximum: 

Input Protection Limits 

Function Maximum 

Input 

V DC or V AC 

600V DC/AC 

3. 

USE EXTREME CAUTION

 when working with voltages greater than 25VAC or 35VDC. These 

voltages are considered a shock hazard. 

4. 

DO NOT

 measure voltage if the voltage on the "COM" input jack exceeds 600V above earth 

ground. 

5. 

NEVER

 connect the meter leads across a voltage source while the function switch is in the 

capacitance, resistance, or diode mode. Doing so can damage the meter. 

6. 

ALWAYS

 discharge filter capacitors in power supplies and disconnect the power when making 

capacitance, resistance, continuity or diode tests. 

7. 

ALWAYS

 turn off the power and disconnect the test leads from the circuit before opening the 

cover to replace the batteries. 

8. 

NEVER

 operate the meter unless the battery cover is in place and fastened securely. 

9. 

NEVER 

operate the meter if any part is damaged. 

10. 

ALWAYS

 turn the meter off when not in use. 

!

Содержание RC200

Страница 1: ...User s Guide R C SMD Tweezers Multimeter Model RC200 ...

Страница 2: ... current to the meter that exceeds the specified maximum Input Protection Limits Function Maximum Input V DC or V AC 600V DC AC 3 USE EXTREME CAUTION when working with voltages greater than 25VAC or 35VDC These voltages are considered a shock hazard 4 DO NOT measure voltage if the voltage on the COM input jack exceeds 600V above earth ground 5 NEVER connect the meter leads across a voltage source ...

Страница 3: ... adaptor 7 Batter compartment rear LCD Display Symbols Low battery Continuity Diode 30V caution icon n nano 10 9 capacitance µ micro 10 6 amps cap m milli 10 3 volts amps k kilo 10 3 ohms F Farads capacitance M mega 10 6 ohms Ω Ohms V Volts AC AC voltage DC DC voltage AUTO Auto Range SCAN SCAN mode APO Auto power off enabled 1 2 3 4 5 6 7 ...

Страница 4: ...uch the red test probe tip to the positive side of the circuit 5 Read the voltage in the display Note The DANGER symbol will appear in the display whenever the measured voltage exceeds 30V WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance or resistance measurements Remove the batteries and unplug line cords Tweezer Re...

Страница 5: ...ECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME the batteries should be removed to prevent damage to the unit BATTERY INSTALLATION 1 Turn power off 2 Open the rear battery cover by removing the two Phillips head screws located on the rear of the meter 3 Insert the batteries into battery holder ob...

Страница 6: ...V Bandwidth 50Hz to 60Hz Display 6000 count liquid crystal Overrange indication OL is displayed Polarity Automatic no indication for positive Minus sign for negative Auto Power Off 10 minutes approx Low Battery Indication is displayed if battery voltage drops below the operating voltage Batteries Two button batteries AG13 LR44 or equivalent Battery life Approximately 60 hours Operating Temperature...

Отзывы: