Power OFF and Auto Power OFF 

Press and hold the MODE button for 4 seconds to manually turn power off. The auto off feature will 
automatically turn the meter off after approximately 10 minutes of inactivity.. 

Low Battery Indication 

The 

 icon will appear in the display when the battery voltage becomes low. Replace the battery 

when this appears.  

Maintenance 

1. 

KEEP THE METER DRY

. If it gets wet, wipe it off. 

2. 

USE AND STORE THE METER IN NORMAL TEMPERATURES.

 Temperature extremes can 

shorten the life of the electronic parts and distort or melt plastic parts. 

3. 

HANDLE THE METER GENTLY AND CAREFULLY.

 Dropping it can damage the electronic 

parts or the case. 

4. 

KEEP THE METER CLEAN.

 Wipe the case occasionally with a damp cloth. DO NOT use 

chemicals, cleaning solvents, or detergents. 

5. 

USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. 

Remove old or 

weak batteries so they do not leak and damage the unit. 

6. 

IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME

, the batteries should be 

removed to prevent damage to the unit. 

BATTERY INSTALLATION 

1. Turn power off. 
2. Open the rear battery cover by removing the two Phillips head screws located on the rear of the 

meter. 

3. Insert the batteries into battery holder, observing the correct polarity. 
4. Put the battery cover back in place. Secure with the screws. 
5.  

You, as the end user, are legally bound (Battery ordinance) to return all used batteries and 
accumulators; disposal in the household garbage is prohibited! 
You can hand over your used batteries / accumulators at collection points in your community 
or wherever batteries / accumulators are sold! 

Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the 
end of its lifecycle 

NOTE

: If your meter does not work properly, check the batteries to make sure that they are still 

good and that they are properly inserted.  

 

 

 
 

Содержание RC200

Страница 1: ...User s Guide R C SMD Tweezers Multimeter Model RC200 ...

Страница 2: ... current to the meter that exceeds the specified maximum Input Protection Limits Function Maximum Input V DC or V AC 600V DC AC 3 USE EXTREME CAUTION when working with voltages greater than 25VAC or 35VDC These voltages are considered a shock hazard 4 DO NOT measure voltage if the voltage on the COM input jack exceeds 600V above earth ground 5 NEVER connect the meter leads across a voltage source ...

Страница 3: ... adaptor 7 Batter compartment rear LCD Display Symbols Low battery Continuity Diode 30V caution icon n nano 10 9 capacitance µ micro 10 6 amps cap m milli 10 3 volts amps k kilo 10 3 ohms F Farads capacitance M mega 10 6 ohms Ω Ohms V Volts AC AC voltage DC DC voltage AUTO Auto Range SCAN SCAN mode APO Auto power off enabled 1 2 3 4 5 6 7 ...

Страница 4: ...uch the red test probe tip to the positive side of the circuit 5 Read the voltage in the display Note The DANGER symbol will appear in the display whenever the measured voltage exceeds 30V WARNING To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance or resistance measurements Remove the batteries and unplug line cords Tweezer Re...

Страница 5: ...ECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit 6 IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME the batteries should be removed to prevent damage to the unit BATTERY INSTALLATION 1 Turn power off 2 Open the rear battery cover by removing the two Phillips head screws located on the rear of the meter 3 Insert the batteries into battery holder ob...

Страница 6: ...V Bandwidth 50Hz to 60Hz Display 6000 count liquid crystal Overrange indication OL is displayed Polarity Automatic no indication for positive Minus sign for negative Auto Power Off 10 minutes approx Low Battery Indication is displayed if battery voltage drops below the operating voltage Batteries Two button batteries AG13 LR44 or equivalent Battery life Approximately 60 hours Operating Temperature...

Отзывы: