PQ3350 V5.2 11/10
8
Current Probe (100A)
WARNING:
All the current probes connected to the power analyzer must be of the same
model and same range. Mixed models and different ranges selected will cause incorrect
result of measurement.
1. Jaw
Assembly
2. Trigger
3. Range
Selector
4.
6 pin mini DIN connector
NOTE: To choose the 100A current probe, press the SETUP button to select CLAMP. When the
CLAMP is reverse video, press the
▲
or
▼
button to select 100.
Current Probe (1000A)
1. Jaw
Assembly
2. Trigger
3. Range
Selector
4.
6 pin mini DIN connector
NOTE: To select the1000A current probe, press the SETUP button to select CLAMP. When the
CLAMP is reverse video, press the
▲
or
▼
button to select 1000.
(HARMON)
(POWER)
(HARMON)
60A
100A
100A
10A
1A
100A
1A
10A
10A
100A
1000A
www.actoolsupply.com
www.actoolsupply.com