background image

MA3010_MA3018

 

en

GB_V1.0

   

1/15

 

4

CAUTIONS

 

 

CAUTIONS

 

identify

 

conditions

 

and

 

actions

 

that

 

could

 

cause

 

DAMAGE

 

to

 

the

 

meter

 

or

 

equipment

 

under

 

test.

 

Do

 

not

 

expose

 

the

 

meter

 

to

 

extremes

 

in

 

temperature

 

or

 

high

 

humidity.

 

Safety

 

Symbols

 

that

 

are

 

typically

 

marked

 

on

 

meters

 

and

 

instructions

 

 

This

 

symbol,

 

adjacent

 

to

 

another

 

symbol,

 

indicates

 

the

 

user

 

must

 

refer

 

to

 

the

 

manual

 

for

 

further

 

information.

 

 

Do

 

not

 

apply

 

or

 

remove

 

clamp

 

from

 

HAZARDOUS

 

LIVE

 

conductors

 

 

Equipment

 

protected

 

by

 

double

 

or

 

reinforced

 

insulation

 

 

Battery

 

symbol

 

 

Conforms

 

to

 

EU

 

directives

 

 

Do

 

not

 

discard

 

this

 

product

 

in

 

household

 

trash.

 

 

AC

 

measurement

 

 

Earth

 

ground

 

 

PER

 

IEC1010

 

OVERVOLTAGE

 

INSTALLATION

 

CATEGORY

 

OVERVOLTAGE

 

CATEGORY

 

I

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

I

 

is

 

equipment

 

for

 

connection

 

to

 

circuits

 

in

 

which

 

measures

 

are

 

taken

 

to

 

limit

 

the

 

transient

 

over

voltages

 

to

 

an

 

appropriate

 

low

 

level.

 

Note

 

 

Examples

 

include

 

protected

 

electronic

 

circuits.

 

OVERVOLTAGE

 

CATEGORY

 

II

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

II

 

is

 

energy

consuming

 

equipment

 

to

 

be

 

supplied

 

from

 

the

 

fixed

 

installation.

 

Note

 

 

Examples

 

include

 

household,

 

office,

 

and

 

laboratory

 

appliances.

 

OVERVOLTAGE

 

CATEGORY

 

III

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

III

 

is

 

equipment

 

in

 

fixed

 

installations.

 

Note

 

 

Examples

 

include

 

switches

 

in

 

the

 

fixed

 

installation

 

and

 

some

 

equipment

 

for

 

industrial

 

use

 

with

 

permanent

 

connection

 

to

 

the

 

fixed

 

installation.

 

OVERVOLTAGE

 

CATEGORY

 

IV

 

Equipment

 

of

 

OVERVOLTAGE

 

CATEGORY

 

IV

 

is

 

for

 

use

 

at

 

the

 

origin

 

of

 

the

 

installation.

 

Note

 

 

Examples

 

include

 

electricity

 

meters

 

and

 

primary

 

over

current

 

protection

 

equipment

 

www.

.com

[email protected]

1.800.561.8187

Содержание MA3010

Страница 1: ...USER GUIDE 3000A TRUE RMS AC Flexible Clamp Meters Model MA3010 and MA3018 www com information itm com 1 800 561 8187...

Страница 2: ...uments that offer Auto Power OFF Data Hold and backlight features This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features 3000A AC True RM...

Страница 3: ...expose this product to rain or moisture Verify the meter operation by measuring a known current If in doubt have the meter serviced Do not apply more than the rated voltage current as marked on the m...

Страница 4: ...t of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electro...

Страница 5: ...Power Hold button 3 Battery Compartment 4 Backlight button 5 LCD display 6 Clamp Lock mechanism Display Icons HOLD Data Hold A Amperes Current Minus symbol negative FULL Battery status message on pow...

Страница 6: ...y after a 20 minute period of inactivity 30 seconds To disable the Auto Power OFF feature With the meter power OFF press and hold the Power button for 2 seconds When the display shows the battery stat...

Страница 7: ...to the device under test 2 Turn the knurled clamp lock mechanism counter clockwise to release the flexible clamp 3 Fully enclose only one conductor of the device under test with the flexible clamp pr...

Страница 8: ...ery compartment 1 With a flat blade screwdriver or coin rotate the battery compartment cover to the unlock position 2 Remove the battery compartment cover 3 Replace the 2 AAA 1 5V batteries observing...

Страница 9: ...ntralized primary conductor at optimum position no external electrical or magnetic field and within operating temperature range MA3010 MA3010 Error MA3018 MA3018 Error Distance from optimum position 1...

Страница 10: ...racy C 18 C 64 5 F 28 C 82 4 F Altitude Maximum operating altitude 2000m 6562 Battery Two AAA 1 5V batteries Battery life 200 hours with alkaline batteries Auto power OFF After approx 20 minutes of in...

Отзывы: