10

GENERAL

 

SPECIFICATIONS

 

Clamp

 

Jaw

 

Flexible

 

type

 

with

 

locking

 

mechanism

 

and

 

7.5mm

 

(0.3”)

 

coil

 

diameter

  

Display

 

3000

 

count

 

LCD

 

with

 

backlight

 

and

 

multi

function

 

indicators

 

Low

 

Battery

 

indication

 

Battery

 

symbol

 

is

 

displayed

 

and

 

text

 

alert

 

is

 

shown

 

upon

 

power

 

up

 

Over

range

 

indication

 

‘OL’

 

display

 

Measurement

 

conversion

 

rate

 

4

 

times

 

per

 

second

 

AC

 

bandwidth

 

45

 

to

 

500Hz

 

(sine

 

wave)

 

AC

 

response

 

True

 

RMS

 

Operating

 

Temperature

 

and

 

Humidity

 

 

0~30

C

 

(32~86

F);

 

80%RH

 

maximum

  

 

30~40

C

 

(86~104

F);

 

75%RH

 

maximum

 

 

40~50

C

 

(104~122

F);

 

45%RH

 

maximum

 

 

Storage

 

Temperature

 

and

 

Humidity

 

 

20

~60

C

 

(

4

~140

F);

 

80%RH

 

maximum

  

Temperature

 

Coefficient

 

0.2

 

x

 

specified

 

accuracy

 

/

 

C,

 

<

 

18

C

 

(64.5

F),

 

>

 

28

C

 

(82.4

F)

 

Altitude

 

Maximum

 

operating

 

altitude

 

2000m

 

(6562’)

 

Battery

 

Two

 

“AAA”

 

1.5V

 

batteries

 

Battery

 

life

 

200

 

hours

 

with

 

alkaline

 

batteries

 

Auto

 

power

 

OFF

 

After

 

approx.

 

20

 

minutes

 

of

 

inactivity

 

Dimensions

 

(W

 

x

 

H

 

x

 

D)

 

MA3010:

 

120

 

x

 

280

 

x

 

25

 

mm

 

(4.7

 

x

 

11.0

 

x

 

1.0”)

 

 

MA3018:

 

130

 

x

 

350

 

x

 

25

 

mm

 

(5.1

 

x

 

13.8

 

x

 

1.0”)

 

Weight

 

MA3010:

 

170g

 

(6.0

 

oz.)

 

/

 

MA3018:

 

200g

 

(7.1

 

oz.)

 

Safety

 

Standards

 

For

 

indoor

 

use

 

and

 

in

 

accordance

 

with

 

the

 

requirements

 

for

 

double

 

insulation

 

to

 

EN61010

1,

 

EN61010

2

032,

 

EN61326

1;

 

CAT

 

IV

 

600V,

 

CAT

 

III

 

1000V,

 

Pollution

 

Degree

 

2

 

Shock

 

Vibration

 

Sinusoidal

 

vibration

 

MIL

PRF

28800F

 

(5

55

 

Hz,

 

3g

 

max.)

 

Drop

 

Protection

 

1.2m

 

(4’)

 

drop

 

onto

 

hardwood

 

or

 

concrete

 

flooring

 

 

Copyright

 

©

 

2015

 

FLIR

 

Systems,

 

Inc.

 

Reservados

 

todos

 

los

 

derechos,

 

incluyendo

 

el

 

derecho

 

de

 

reproducción

 

total

 

o

 

parcial

 

en

 

cualquier

 

medio

 

www.extech.com

 

www.

.com

[email protected]

1.800.561.8187

Содержание MA3010

Страница 1: ...USER GUIDE 3000A TRUE RMS AC Flexible Clamp Meters Model MA3010 and MA3018 www com information itm com 1 800 561 8187...

Страница 2: ...uments that offer Auto Power OFF Data Hold and backlight features This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features 3000A AC True RM...

Страница 3: ...expose this product to rain or moisture Verify the meter operation by measuring a known current If in doubt have the meter serviced Do not apply more than the rated voltage current as marked on the m...

Страница 4: ...t of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electro...

Страница 5: ...Power Hold button 3 Battery Compartment 4 Backlight button 5 LCD display 6 Clamp Lock mechanism Display Icons HOLD Data Hold A Amperes Current Minus symbol negative FULL Battery status message on pow...

Страница 6: ...y after a 20 minute period of inactivity 30 seconds To disable the Auto Power OFF feature With the meter power OFF press and hold the Power button for 2 seconds When the display shows the battery stat...

Страница 7: ...to the device under test 2 Turn the knurled clamp lock mechanism counter clockwise to release the flexible clamp 3 Fully enclose only one conductor of the device under test with the flexible clamp pr...

Страница 8: ...ery compartment 1 With a flat blade screwdriver or coin rotate the battery compartment cover to the unlock position 2 Remove the battery compartment cover 3 Replace the 2 AAA 1 5V batteries observing...

Страница 9: ...ntralized primary conductor at optimum position no external electrical or magnetic field and within operating temperature range MA3010 MA3010 Error MA3018 MA3018 Error Distance from optimum position 1...

Страница 10: ...racy C 18 C 64 5 F 28 C 82 4 F Altitude Maximum operating altitude 2000m 6562 Battery Two AAA 1 5V batteries Battery life 200 hours with alkaline batteries Auto power OFF After approx 20 minutes of in...

Отзывы: