background image

MA3010_MA3018

 

en

GB_V1.0

   

1/15

 

3

Safety

 

Information

 

To

 

ensure

 

the

 

safe

 

operation

 

and

 

service

 

of

 

the

 

meter,

 

follow

 

these

 

instructions

 

closely.

 

Failure

 

to

 

observe

 

warnings

 

can

 

result

 

in

 

severe

 

injury.

 

 

WARNINGS

 

 

WARNINGS

 

identify

 

hazardous

 

conditions

 

and

 

actions

 

that

 

could

 

cause

 

BODILY

 

HARM

 

or

 

DEATH.

 

 

Individual

 

protective

 

equipment

 

should

 

be

 

used

 

if

 

HAZARDOUS

 

LIVE

 

parts

 

in

 

the

 

installation

 

where

 

measurements

 

are

 

to

 

be

 

carried

 

out

 

could

 

be

 

accessible.

 

 

If

 

the

 

equipment

 

is

 

used

 

in

 

a

 

manner

 

not

 

specified

 

by

 

the

 

manufacturer,

 

the

 

protection

 

provided

 

by

 

the

 

equipment

 

may

 

be

 

impaired.

 

 

To

 

reduce

 

the

 

risk

 

of

 

fire

 

or

 

electric

 

shock,

 

do

 

not

 

expose

 

this

 

product

 

to

 

rain

 

or

 

moisture.

 

 

Verify

 

the

 

meter

 

operation

 

by

 

measuring

 

a

 

known

 

current.

 

If

 

in

 

doubt,

 

have

 

the

 

meter

 

serviced.

 

 

Do

 

not

 

apply

 

more

 

than

 

the

 

rated

 

voltage/current

 

as

 

marked

 

on

 

the

 

meter.

 

 

To

 

avoid

 

false

 

readings

 

that

 

can

 

lead

 

to

 

electric

 

shock

 

and

 

injury,

 

replace

 

battery

 

as

 

soon

 

as

 

the

 

low

 

battery

 

indicator

 

appears.

 

 

Do

 

not

 

use

 

the

 

meter

 

in

 

or

 

around

 

explosive

 

gas

 

or

 

vapor.

 

 

Do

 

not

 

use

 

a

 

flexible

 

current

 

sensor

 

if

 

the

 

inner

 

copper

 

wire

 

of

 

the

 

flexible

 

cord

 

is

 

visible.

 

 

De

energize

 

the

 

installation

 

under

 

test

 

or

 

wear

 

suitable

 

protective

 

clothing

 

when

 

placing

 

or

 

removing

 

the

 

flexible

 

current

 

probe

 

from

 

a

 

test

 

setup.

 

 

Do

 

not

 

apply/remove

 

the

 

flexible

 

current

 

probe

 

to/from

 

UNINSULATED

 

HAZARDOUS

 

LIVE

 

conductors

 

which

 

may

 

cause

 

electric

 

shock,

 

electric

 

burn,

 

or

 

arc

 

flash.

 

www.

.com

[email protected]

1.800.561.8187

Содержание MA3010

Страница 1: ...USER GUIDE 3000A TRUE RMS AC Flexible Clamp Meters Model MA3010 and MA3018 www com information itm com 1 800 561 8187...

Страница 2: ...uments that offer Auto Power OFF Data Hold and backlight features This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features 3000A AC True RM...

Страница 3: ...expose this product to rain or moisture Verify the meter operation by measuring a known current If in doubt have the meter serviced Do not apply more than the rated voltage current as marked on the m...

Страница 4: ...t of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over voltages to an appropriate low level Note Examples include protected electro...

Страница 5: ...Power Hold button 3 Battery Compartment 4 Backlight button 5 LCD display 6 Clamp Lock mechanism Display Icons HOLD Data Hold A Amperes Current Minus symbol negative FULL Battery status message on pow...

Страница 6: ...y after a 20 minute period of inactivity 30 seconds To disable the Auto Power OFF feature With the meter power OFF press and hold the Power button for 2 seconds When the display shows the battery stat...

Страница 7: ...to the device under test 2 Turn the knurled clamp lock mechanism counter clockwise to release the flexible clamp 3 Fully enclose only one conductor of the device under test with the flexible clamp pr...

Страница 8: ...ery compartment 1 With a flat blade screwdriver or coin rotate the battery compartment cover to the unlock position 2 Remove the battery compartment cover 3 Replace the 2 AAA 1 5V batteries observing...

Страница 9: ...ntralized primary conductor at optimum position no external electrical or magnetic field and within operating temperature range MA3010 MA3010 Error MA3018 MA3018 Error Distance from optimum position 1...

Страница 10: ...racy C 18 C 64 5 F 28 C 82 4 F Altitude Maximum operating altitude 2000m 6562 Battery Two AAA 1 5V batteries Battery life 200 hours with alkaline batteries Auto power OFF After approx 20 minutes of in...

Отзывы: