Max/Min  

1.  Press the 

MAX/MIN

 button to activate the MAX/MIN recording mode. The display icon "

MAX

will appear. The meter will begins recording and displaying the maximum value measured. 

2.  Press the 

MAX/MIN

 button and “

MIN

” will appear. The meter will display the minimum value 

measured during the recording session. 

3.  Press the 

MAX/MIN

 button and “

MAX

 

MIN

” will appear. The meter will display the present 

reading, but will continue to update and store the max and min readings. 

4.  To exit MAX/MIN mode press and hold the 

MAX/MIN

 button for 2 seconds. 

 

Peak Hold 

When ACA or ACV is selected, pressing the 

PEAK

 button enables the peak capture circuit. The 

meter will now capture and display the maximum and minimum peaks of the waveform. 

Inrush 

With ACA is selected, press the 

INRUSH

 button to activate the inrush capture circuit,  

“- - - -“ will appear in the display. Any transient condition, generally lasting 110-120 milliseconds, 

that occurs during motor start-up will be captured in the display. 

Range 

In the Voltage, Resistance, Capacitance, Frequency or μA function the meter automatically selects 

the best range for the measurements being made. For measurement situations requiring that a 

range be manually selected, perform the following: 

1.  Press the

 RANGE

 button. The “

AUTO”

 display icon will turn off. 

2.  Press the 

RANGE

 key to step through the available ranges. Observe the decimal point and 

units displayed until the preferred range is located. 

3.  To exit the Manual Ranging mode and return to Autoranging, press and hold the

 RANGE

 key 

for 2 seconds. 

LCD Backlight 

The LCD is equipped with backlighting for easier viewing, especially in dimly lit areas. Press   to 

turn the backlight on and again to turn it off.  

Automatic Power OFF with Disable 

In order to conserve battery life, the meter will automatically turn off after approximately 30 minutes. 

To turn the meter on again, turn the function switch to the OFF position and then turn to the desired 

function position. 
To disable APO: 

1.  From the OFF position, hold the MODE button and rotate the FUNCTION switch to a 

measurement function. 

2. 

 will appear in the display 

3.  Release the MODE button 
4.  APO is now disabled (APO icon is off) and will be reset when the Function switch is returned to 

the OFF position. 

Low battery indication 

When the 

 icon and “-----“appears in the display, the battery should be replaced. Refer to the 

battery replacement procedure in the maintenance section. 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA1500

Страница 1: ...User Manual 1500Amp True RMS AC DC Clamp Meter Model MA1500 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...voided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measur...

Страница 3: ...discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltage checks on electrical outlets can be difficult and misleading because of...

Страница 4: ...input jacks Display icons Description HOLD Data Hold APO Auto Power Off AUTO Autoranging P Peak Hold DC Direct Current AC Alternating Current MAX Max reading MIN Min reading Low battery ZERO DCA or CA...

Страница 5: ...ed with high sensitivity Static electricity or other sources of energy may randomly trip the sensor This is normal operation AC DC Current Measurements WARNING Disconnect the test leads before measuri...

Страница 6: ...be measured Touch the red test probe tip to the other side of the device to be measured 4 Read the resistance value in the display Continuity Test 1 Set the function switch to the position 2 Insert th...

Страница 7: ...MA1500 en GB_v1 4 10 18 7 If both readings are very small or 0 the device is shorted www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 8: ...e Hz position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive Hz jack 3 Touch the black test probe tip to one side of the dev...

Страница 9: ...measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The AUTO display icon will turn off 2 Press the RANGE key to step through the availabl...

Страница 10: ...crew secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the battery compartment door with the screw Never dispose of used batteries or rechargeable batterie...

Страница 11: ...nge Resistance 400 00 0 5 9 digits 4 0000 k 1 0 4 digits 40 000 k 400 00 k 4 0000 M 2 0 10 digits 40 000 M 3 0 10 digits Capacitance 400 00 nF 3 5 reading 40 digits 4000 0 nF 3 5 reading 10 digits 40...

Страница 12: ...C and VAC Crest Factor 3 0 in 400A range 1 4 in 1000A range 50 60Hz and 5 to 100 of range Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidi...

Отзывы: