General Specifications 

Clamp jaw opening 

52mm (2.0") approx. 

Display 

Dual 40,000/4,000 count backlit LCD 

Continuity check 

Threshold 25 to 60

; Test current < 0.5mA 

Diode test 

Test current of 0.3mA typical; 

 

Open circuit voltage 2.8VDC typical 

Low Battery indication

 

Battery symbol is displayed 

Over-range indication

 

‘OL’ display 

Measurement rate 

2 readings per second, nominal 

Peak detector 

>1ms 

Thermocouple sensor

 

Type K thermocouple required 

Input Impedance 

10M

 (VDC and VAC) 

AC bandwidth 

50 to 400Hz (AAC and VAC) 

AC response 

True rms (AAC and VAC)  

Crest Factor 

3.0 in 400A range, 1.4 in 1000A range (50/60Hz and 5% to 100% of 

range) 

Operating Temperature 

5

C to 40

C (41

F to 104

F)

 

Storage Temperature 

-20

C to 60

C (-4

F to 140

F)

 

Operating Humidity 

Max 80% up to 31

C (87

F) decreasing linearly to 50% at 40

(104

F) 

Storage Humidity 

<80%  

Operating Altitude 

2000meters (7000ft.) maximum. 

Battery 

One (1) 9V Battery (NEDA 1604) 

Auto power OFF 

After approx. 30 minutes 

Dimensions & Weight

 

294x105x47mm (11.57x4.13x1.85”); 536g (18.9 oz) 

Safety 

For indoor use and in accordance with the requirements for double 

insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage 

Category IV 600V and Category III 1000V, Pollution Degree 2.  

Approvals 

CE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA1500

Страница 1: ...User Manual 1500Amp True RMS AC DC Clamp Meter Model MA1500 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...voided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measur...

Страница 3: ...discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltage checks on electrical outlets can be difficult and misleading because of...

Страница 4: ...input jacks Display icons Description HOLD Data Hold APO Auto Power Off AUTO Autoranging P Peak Hold DC Direct Current AC Alternating Current MAX Max reading MIN Min reading Low battery ZERO DCA or CA...

Страница 5: ...ed with high sensitivity Static electricity or other sources of energy may randomly trip the sensor This is normal operation AC DC Current Measurements WARNING Disconnect the test leads before measuri...

Страница 6: ...be measured Touch the red test probe tip to the other side of the device to be measured 4 Read the resistance value in the display Continuity Test 1 Set the function switch to the position 2 Insert th...

Страница 7: ...MA1500 en GB_v1 4 10 18 7 If both readings are very small or 0 the device is shorted www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 8: ...e Hz position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive Hz jack 3 Touch the black test probe tip to one side of the dev...

Страница 9: ...measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The AUTO display icon will turn off 2 Press the RANGE key to step through the availabl...

Страница 10: ...crew secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the battery compartment door with the screw Never dispose of used batteries or rechargeable batterie...

Страница 11: ...nge Resistance 400 00 0 5 9 digits 4 0000 k 1 0 4 digits 40 000 k 400 00 k 4 0000 M 2 0 10 digits 40 000 M 3 0 10 digits Capacitance 400 00 nF 3 5 reading 40 digits 4000 0 nF 3 5 reading 10 digits 40...

Страница 12: ...C and VAC Crest Factor 3 0 in 400A range 1 4 in 1000A range 50 60Hz and 5 to 100 of range Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidi...

Отзывы: