Extech Instruments MA1500 Скачать руководство пользователя страница 6

 

MA1500-en-GB_v1.4   10/18 

AC/DC Voltage Measurements

  

CAUTION: 

 Do not measure voltages if a motor on the circuit is being switched ON or OFF. Large 

voltage surges may occur that can damage the meter. 

 

1.  Rotate the function switch to the 

V

 position.  

2.  Press the 

MODE

 button to select AC or DC Voltage. 

3.  Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

V

 jack. 

4.  Touch the black test probe tip to the negative side of the circuit.  

Touch the red test probe tip to the positive side of the circuit. 

5.  Read the voltage value in the display. 

Frequency

 

When ACV is selected, the measured frequency can be viewed in the 

lower display. 

Resistance Measurements 

Note: Remove power from the device under test before measuring resistance. 

1.  Set the function switch to the 



position. 

2.  Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

V

 jack. 

3.  Touch the black test probe tip to one side of the device to be measured.  

Touch the red test probe tip to the other side of the device to be measured. 

4.  Read the resistance value in the display. 

Continuity Test 

1.  Set the function switch to the 

)

)

position. 

2.  Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

V

 jack. 

3.  Press the 

MODE

 button to select 

)

)

(continuity). 

4.  Touch the test probe tips across the circuit or component under test. 
5.  If the resistance is less than the continuity threshold,

 

a tone will sound. 

Diode Test 

1.  Set the function switch to the 

position. 

2.  Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

V

 jack. 

3.  Press the 

MODE

 button to select 

 (diode). 

4.  Touch the test probe tips to the diode or semiconductor junction under test. Note the meter 

reading. 

5.  Reverse the test lead polarity by reversing the red and black leads. Note this reading. 
6.  The diode or junction can be evaluated as follows: 

  If one reading displays a value (typically 0.400V to 01.800V) and the other reading 

displays 

OL

, the diode is good. 

  If both readings display 

OL

 the device is open. 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA1500

Страница 1: ...User Manual 1500Amp True RMS AC DC Clamp Meter Model MA1500 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...voided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which measur...

Страница 3: ...discharge capacitors and remove power from the device under test before performing Diode Resistance or Continuity tests Voltage checks on electrical outlets can be difficult and misleading because of...

Страница 4: ...input jacks Display icons Description HOLD Data Hold APO Auto Power Off AUTO Autoranging P Peak Hold DC Direct Current AC Alternating Current MAX Max reading MIN Min reading Low battery ZERO DCA or CA...

Страница 5: ...ed with high sensitivity Static electricity or other sources of energy may randomly trip the sensor This is normal operation AC DC Current Measurements WARNING Disconnect the test leads before measuri...

Страница 6: ...be measured Touch the red test probe tip to the other side of the device to be measured 4 Read the resistance value in the display Continuity Test 1 Set the function switch to the position 2 Insert th...

Страница 7: ...MA1500 en GB_v1 4 10 18 7 If both readings are very small or 0 the device is shorted www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 8: ...e Hz position 2 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive Hz jack 3 Touch the black test probe tip to one side of the dev...

Страница 9: ...measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE button The AUTO display icon will turn off 2 Press the RANGE key to step through the availabl...

Страница 10: ...crew secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the battery compartment door with the screw Never dispose of used batteries or rechargeable batterie...

Страница 11: ...nge Resistance 400 00 0 5 9 digits 4 0000 k 1 0 4 digits 40 000 k 400 00 k 4 0000 M 2 0 10 digits 40 000 M 3 0 10 digits Capacitance 400 00 nF 3 5 reading 40 digits 4000 0 nF 3 5 reading 10 digits 40...

Страница 12: ...C and VAC Crest Factor 3 0 in 400A range 1 4 in 1000A range 50 60Hz and 5 to 100 of range Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 20 C to 60 C 4 F to 140 F Operating Humidi...

Отзывы: