background image

HDV

WTX2L

en

GB_V1.1

   

2/16

 

Articulation

 

Setup

 

and

 

Orientation

 

 

The

 

articulation

 

direction

 

and

 

orientation

 

may

 

change

 

if

 

the

 

probe

 

is

 

twisted

 

and

 

coiled

 

during

 

use

 

or

 

when

 

stored.

 

To

 

re

orient

 

the

 

probe:

 

1.

 

Place

 

the

 

extended

 

probe

 

on

 

a

 

flat

 

surface

 

2.

 

Set

 

the

 

tension

 

“F”

 

knob

 

to

 

the

 

left

 

or

 

released

 

position.

 

3.

 

Set

 

the

 

articulation

 

knob

 

to

 

the

 

center

 

position

 

with

 

the

 

R

 Δ 

and

 Δ 

L

 

labels

 

in

 

the

 

horizontal

 

position.

 

4.

 

Manually

 

adjust

 

the

 

probe

 

and

 

camera

 

to

 

the

 

zero

 

degree

 

position.

 

5.

 

Rotate

 

the

 

articulation

 

knob

 

clockwise

 

for

 

a

 

90°

 

bend.

 

6.

 

If

 

necessary,

 

manually

 

adjust

 

the

 

probe

  

so

 

that

 

the

 

camera

 

lays

 

flat

 

on

 

the

 

surface

 

with

 

a

 

90°

 

articulation

 

7.

 

Rotate

 

the

 

articulation

 

knob

 

counter

clockwise

 

and

 

confirm

 

proper

 

orientation.

 

 

Charging

 

the

 

Probe

 

Battery

 

The

 

probe

 

battery

 

can

 

be

 

charged

 

in

 

two

 

ways:

 

1.

 

Charge

 

the

 

probe

 

with

 

its

 

own

 

charging

 

cable.

 

The

 

AC

 

charger

 

port

 

and

 

charging

 

status

 

LED

 

are

 

located

 

in

 

the

 

bottom

 

access

 

compartment.

 

Connect

 

the

 

charger

 

to

 

the

 

probe

 

and

 

observe

 

the

 

color

 

of

 

the

 

LED:

 

Red

 

indicates

 

charging;

 

Green

 

indicates

 

fully

 

charged.

 

2.

 

Charge

 

the

 

probe

 

through

 

the

 

camera.

 

Connect

 

the

 

camera

 

to

 

the

 

probe

 

via

 

the

 

extension

 

cable

 

(bottom

 

access

 

compartment

 

jack).

 

Make

 

sure

 

that

 

the

 

charging

 

cable

 

is

 

disconnected

 

from

 

the

 

probe

 

and

 

then

 

connect

 

a

 

charging

 

cable

 

to

 

the

 

camera.

 

Now

 

while

 

the

 

camera

 

is

 

charging,

 

the

 

probe

 

will

 

charge

 

at

 

the

 

same

 

time.

  

Note:

 

The

 

rechargeable

 

battery

 

is

 

not

 

user

 

replaceable.

 

 

Specifications

 

 

Resolution

 

640

 

x

 

480

 

pixels

 

Length

 

2m

 

(6.6’)

 

Outer

 

diameter

 

(O.D.)

 

6mm

 

(0.24”)

 

Battery

 

3.7V

 

rechargeable

 

Li

Polymer

 

Focus

 

distance

 

6cm

 

to

 

 

(2.36”

 

to

 

)

 

Housing

 

Stainless

 

Steel

 

Field

 

of

 

View

 

60º

 

Number

 

of

 

LEDs

 

4

 

Lamp

 

Output

 

3500

 

Lux

 

at

 

20mm

 

(0.8”)

 

Operating

 

Temperature

 

20

 

to

 

70°C

 

(

4

 

to

 

158°F)

 

Storage

 

Temperature

 

20

 

to

 

70°C

 

(

4

 

to

 

158°F)

 

Warranty

 

1

 

year

 

 

Copyright

 

©

 

2013

2016

 

FLIR

 

Systems,

 

Inc.

 

All

 

rights

 

reserved

 

including

 

the

 

right

 

of

 

reproduction

 

in

 

whole

 

or

 

in

 

part

 

in

 

any

 

form

 

ISO

9001

 

Certified

 

www.extech.com

 