5. Operation

Note: 

The DCP42 Total Output Voltage Range is 42VDC and the Total Rated Current is 0 to 10ADC

 

 

5.1 Powering the Supply 

Check the rating label of the power supply and ensure that it complies with the AC mains voltage 
that is to be used. Connect the power supply to the AC Mains using the provided power cord.  

5.2 Switching the Power Supply ON and Self-Test Information 

The power supply will perform a series of self-tests when it is switched ON. The LED and other 
indicators on the front panel will illuminate in sequence. When the cooling fan is being checked, 
a high speed wind sound can be heard. After the self-tests, the 

CV

V

 and 

A

 LED indicators are lit 

and the unit displays voltage and 0.0 current. To find the CC current level, turn the current 
control knob one click in either direction. The current display returns to 0.0 after a few seconds.  

5.3 Using the Control knobs 

The rotary encoder control knobs have fine and coarse tuning with ‘clicking’ movement. Push 
the knobs to toggle between coarse and fine tuning, notice the subtle changes in brightness of 
the related LED. Adjust the knobs to the desired values by using coarse and then fine tuning. 
The display will resume its normal brightness after few seconds to confirm an adjustment. 

5.4 Connecting the Power Supply and running a Test 

1.

Connect the equipment under test to the power supply. Red (+) is connected to the positive
polarity input of the equipment and Black (-) is connected to the negative polarity input of
the equipment.

2.

Switch ON the power supply first; the panel meter & green CV Indicator should illuminate.

3.

Next, switch ON the equipment under test; the panel meter & green CV Indicator should 
remain lit in green.

4.

Testing can now begin.

5.

When finished, switch OFF the equipment under test first and then switch off the power
supply.

5.5 Keypad Lockout function 

1.

Press LOCK/UNLOCK to lock or unlock all of the function buttons and control knobs on the 
front panel.

2.

The LOCK/UNLOCK button light switches ON when the push-buttons are locked.

5.6 Manual Output ON/OFF 

1.

Press OUTPUT ON/OFF button to manually set the output ON or OFF.

2.

The OUTPUT ON/OFF button light switches ON when the output is ON.

5.7 Ammeter/Wattmeter Selection 

1.

Press the SHIFT button and then press the LOCK/UNLOCK button to change from Ammeter
mode to Wattmeter mode.

2.

To change back to Ammeter mode from Wattmeter mode, press the SHIFT button and press 
the LOCK/UNLOCK button.

actoolsupply.com

actoolsupply.com

Содержание DCP42

Страница 1: ...USER GUIDE Model DCP42 160W Laboratory Grade Constant Power Switching Mode Power Supply actoolsupply com actoolsupply com actoolsupply com Extech DCP42 160W Single Continuous Switching Power Supply...

Страница 2: ...emote Control Mode 8 4 3 3 Deactivating the Remote Control Mode 8 4 3 4 Factory Default Reset 8 5 OPERATION 9 5 1 Powering the Supply 9 5 2 Switching the Power Supply ON and Self Test Information 9 5...

Страница 3: ...nection 12 6 4 2 Disconnection 12 6 5 Remote Control Operation 13 6 5 1 REMOTE CONTROL METHOD 1 Using two external DC voltage sources 13 6 5 2 REMOTE CONTROL METHOD 2 Using two 0 to 5K Ohm variable re...

Страница 4: ...te and quick setting of Voltage Current Setting changing and verifying the current limit level is convenient and can be performed without output pole spiking The Remote Control feature permits output...

Страница 5: ...e first Replace the AC fuse with the same type and rating as the original fuse The maximum output voltage of the DCP42 exceeds 60VDC avoid touching the metal contact parts at the output terminals CAUT...

Страница 6: ...2 3 Menu Key Shift Key Lock Unlock Key A W meter Key Output ON OFF V t Key 7 Output Safety Jacks Rated 10A 8 USB Remote Control port For access to computer to run cyclical operation with programmable...

Страница 7: ...er can change these output settings using the voltage and current knobs Recall No Output Voltage Output Current P1 5V Maximum P2 13 8V Maximum P3 40V Maximum 4 3 Set Mode Enter the Set Mode by pushing...

Страница 8: ...ode all function keys located on the front panel will be locked the Lock Unlock button light switches ON 4 3 3 Deactivating the Remote Control Mode a Press Lock Unlock button to unlock all the functio...

Страница 9: ...values by using coarse and then fine tuning The display will resume its normal brightness after few seconds to confirm an adjustment 5 4 Connecting the Power Supply and running a Test 1 Connect the eq...

Страница 10: ...etting as an example turn the Voltage control knob until A b appears on the voltmeter display and then turn the Current control knob to set to desired transit time t 5 seconds for example 6 1 3 Genera...

Страница 11: ...1 Pulse waveform with 3sec at 10V and 1sec at 5V Set A Preset 1 5V set B Preset 2 10V Set Func A 1 second by turning the Current control knob Func B 3 seconds using the same procedure as above Set t...

Страница 12: ...return to normal operation Note The UVL and UCL settings default to the maximum output value 6 4 Remote Sensing Note Observe warnings displayed by the Power Supply an incorrect disconnection sequence...

Страница 13: ...by varying the external voltage source Short circuit the main output with 14AWG wire to check the CC setting on the display while varying the external voltage source 6 5 2 REMOTE CONTROL METHOD 2 Usin...

Страница 14: ...e the software please refer to the instructions provided on the supplied CD ROM and or the instructions provided in the HELP Utility within the software program Check the software download page of the...

Страница 15: ...t keys on PC keyboard for new locations 3 Data that exceed the rated voltage and current will not be accepted 4 Voltages that exceed the UVL Upper Voltage Limit will not be accepted 5 If retrieved or...

Страница 16: ...Set t b a 2 seconds Set Func A 3 seconds Set Func B 3 seconds Example 4 Irregular waveform Set A 5V B 10 V Set t a b 2 second Set t b a 2 seconds Set Func A 2 seconds Set Func B 6 seconds Example 5 I...

Страница 17: ...tage 80mVp p Current Ripple Noise peak peak 50mA Meter Type Accuracy Voltage Meter 4 Digit LED Display 0 1 5 counts Current Meter 4 Digit LED Display 0 1 5 counts Resolution Output Voltage Resolution...

Страница 18: ...1 5KVac O P F G 0 5KVac Insulation Resistance I P O P I P F G O P F G 100Mohm 500Vdc EMC CE EN55011 Harmonics Current Emission EN 61000 3 2 Voltage Fluctuations Flicker EN 61000 3 3 EMC Immunity EN 61...

Страница 19: ...nit to cool for at least 30 minutes Check to see if any ventilation holes are blocked also check that there is sufficient clearance around the power supply Listen carefully for the short wind sound em...

Отзывы: