1. Introduction and Features

Thank you for selecting the Extech DCP42 Switching Mode Power Supply.  This newly re-designed 
laboratory grade power supply differs from a conventional power supply in that it can calculate 
and change the voltage and current limit points according to the available maximum power. 
Therefore the maximum limits of the voltage and current are changeable according to the rated 
power. A conventional power supply has only a set maximum voltage and current such that all of 
the operating V & A must fall within these limits. The DCP42 offers cost saving and space saving 
advantages as one constant-power power supply can do the work of several conventional power 
suppliers. 

The DCP42 is highly efficient, incorporates upgraded SMPS circuitry with small form factor, benefits 
from an automatic cross-over for CC and CV, has three (3) Voltage/Current presets, and can be 
remote controlled. The DCP42 is perfect for solving a variety of loading conditions and applications. 
Features include the following: 

Dual action (Course/Fine) tuning provides smooth, accurate, and quick setting of
Voltage/Current

Setting, changing, and verifying the current limit level is convenient and can be 
performed without output pole spiking

The Remote Control feature permits output ON/OFF and Voltage/Current adjustments 
without the need to touch the front panel of the power supply

The USB port offers PC connectivity for programming and running ramp/soak cycles with 
20 programmable sets of Voltage/Current and varying test durations (up to 999 cycles)

The DC ramp and waveform generator can either be panel set or set by the supplied 
software which previews the final waveform.

Applications and industries where the DCP42 can be employed include laboratory,
telecommunications, production testing, field testing, DC network powering, and more

Three (3) user programmable Voltage/Current settings offer quick recall of frequently
used test settings

The DCP42 is suitable for a wide range of applications such as laboratory, production 
testing, field test of remote critical voltage loads, powering of dc networks, and more.

This device is shipped fully tested and calibrated and, with proper use, will provide years of 
reliable service. Please visit our website  to check for the latest version of this User Guide, Product 
Updates, and Customer Support. 

actoolsupply.com

actoolsupply.com

Содержание DCP42

Страница 1: ...USER GUIDE Model DCP42 160W Laboratory Grade Constant Power Switching Mode Power Supply actoolsupply com actoolsupply com actoolsupply com Extech DCP42 160W Single Continuous Switching Power Supply...

Страница 2: ...emote Control Mode 8 4 3 3 Deactivating the Remote Control Mode 8 4 3 4 Factory Default Reset 8 5 OPERATION 9 5 1 Powering the Supply 9 5 2 Switching the Power Supply ON and Self Test Information 9 5...

Страница 3: ...nection 12 6 4 2 Disconnection 12 6 5 Remote Control Operation 13 6 5 1 REMOTE CONTROL METHOD 1 Using two external DC voltage sources 13 6 5 2 REMOTE CONTROL METHOD 2 Using two 0 to 5K Ohm variable re...

Страница 4: ...te and quick setting of Voltage Current Setting changing and verifying the current limit level is convenient and can be performed without output pole spiking The Remote Control feature permits output...

Страница 5: ...e first Replace the AC fuse with the same type and rating as the original fuse The maximum output voltage of the DCP42 exceeds 60VDC avoid touching the metal contact parts at the output terminals CAUT...

Страница 6: ...2 3 Menu Key Shift Key Lock Unlock Key A W meter Key Output ON OFF V t Key 7 Output Safety Jacks Rated 10A 8 USB Remote Control port For access to computer to run cyclical operation with programmable...

Страница 7: ...er can change these output settings using the voltage and current knobs Recall No Output Voltage Output Current P1 5V Maximum P2 13 8V Maximum P3 40V Maximum 4 3 Set Mode Enter the Set Mode by pushing...

Страница 8: ...ode all function keys located on the front panel will be locked the Lock Unlock button light switches ON 4 3 3 Deactivating the Remote Control Mode a Press Lock Unlock button to unlock all the functio...

Страница 9: ...values by using coarse and then fine tuning The display will resume its normal brightness after few seconds to confirm an adjustment 5 4 Connecting the Power Supply and running a Test 1 Connect the eq...

Страница 10: ...etting as an example turn the Voltage control knob until A b appears on the voltmeter display and then turn the Current control knob to set to desired transit time t 5 seconds for example 6 1 3 Genera...

Страница 11: ...1 Pulse waveform with 3sec at 10V and 1sec at 5V Set A Preset 1 5V set B Preset 2 10V Set Func A 1 second by turning the Current control knob Func B 3 seconds using the same procedure as above Set t...

Страница 12: ...return to normal operation Note The UVL and UCL settings default to the maximum output value 6 4 Remote Sensing Note Observe warnings displayed by the Power Supply an incorrect disconnection sequence...

Страница 13: ...by varying the external voltage source Short circuit the main output with 14AWG wire to check the CC setting on the display while varying the external voltage source 6 5 2 REMOTE CONTROL METHOD 2 Usin...

Страница 14: ...e the software please refer to the instructions provided on the supplied CD ROM and or the instructions provided in the HELP Utility within the software program Check the software download page of the...

Страница 15: ...t keys on PC keyboard for new locations 3 Data that exceed the rated voltage and current will not be accepted 4 Voltages that exceed the UVL Upper Voltage Limit will not be accepted 5 If retrieved or...

Страница 16: ...Set t b a 2 seconds Set Func A 3 seconds Set Func B 3 seconds Example 4 Irregular waveform Set A 5V B 10 V Set t a b 2 second Set t b a 2 seconds Set Func A 2 seconds Set Func B 6 seconds Example 5 I...

Страница 17: ...tage 80mVp p Current Ripple Noise peak peak 50mA Meter Type Accuracy Voltage Meter 4 Digit LED Display 0 1 5 counts Current Meter 4 Digit LED Display 0 1 5 counts Resolution Output Voltage Resolution...

Страница 18: ...1 5KVac O P F G 0 5KVac Insulation Resistance I P O P I P F G O P F G 100Mohm 500Vdc EMC CE EN55011 Harmonics Current Emission EN 61000 3 2 Voltage Fluctuations Flicker EN 61000 3 3 EMC Immunity EN 61...

Страница 19: ...nit to cool for at least 30 minutes Check to see if any ventilation holes are blocked also check that there is sufficient clearance around the power supply Listen carefully for the short wind sound em...

Отзывы: