DCP42-EU-EN V1.2 9/13
18
Switching Frequency
45-55 KHz~
Tracking Over Voltage Protections
O/P 0-10V: Set (1.0 ±0.3V)
O/P 10-42V: 105-125% of set voltage
Power Factor
Control Power factor correction: >0.91 at optimal load
Cooling Method
Natural Convection
Leakage Current
≤2mA
Protections
Adjustable upper voltage limit, Adjustable upper current limit, Short Circuit, Overload,
Over Temperature , Tracking OVP
Input Fuse
T3.15AL250V
Safety & EMC
Safety Standard CE: EN 61010
Withstanding Voltage I/P-O/P: 3.0KVac, I/P-F/G: 1.5KVac, O/P-F/G: 0.5KVac
Insulation Resistance I/P-O/P, I/P-F/G, O/P-F/G : 100Mohm @500Vdc
EMC CE: EN55011
Harmonics Current Emission EN 61000-3-2
Voltage Fluctuations & Flicker EN 61000-3-3
EMC Immunity EN 61000-6-1
Environmental
Working Temperature 0 to +40°C (32 to +104°F)
Working Humidity 10-80% RH Non-condensing
Storage Temperature and Humidity -15 to +70°C (5 to 158°F) 10-85% RH Non-condensing
Pollution Degree Class 2
General
Case Material Polycarbonate Front Panel and Electro-Galvanized Steel Enclosure
Case Protection IP20
Connection Dia. 4.0mm Safety Jack x3 (Output Positive, Negative and Function Ground)
Dimensions (WxHxD) 200 x 90 x 250 mm (7.9 x 3.6 x 10 inch)
Weight 2.5 kg (5.5 lb)