manualshive.com logo in svg
background image

User  Guide 

Circuit Breaker Finder and  GFCI 

Receptacle Tester 

Extech  CB10 

EXTECH' 

=INsrRU�ENTS 

Fi� 

CB10 

Introduction 

Gf(]Tesler 

Tra/lSMltltlforCB10 

Congratulations on your purchase of the  Extech Model 
CB10 Circuit Breaker Finder  and Receptacle Tester.  This 
instrument is shipped  fully tested and calibrated and,  with 
proper use,  will provide years of  reliable service. 

Meter 

Receiver 

1. 

2. 

3. 

Indicating L ED  and 

ON/OFF  and  Sensitivity 

Transmitter storage 

Note  that battery compartment is 

on 

rear of  receiver 

Transmitter 

4. 

Receptacle  LED  coding scheme 

5. 

GFCI  test button 

6. 

Receptacle LED's 

This symbol adjacent to another symbol, 
terminal or operating device indicates that 
the operator  must refer to an explanation in 
the  Operatingilnstructions to  avoid personal 
injury  or  dam9ge  to  the  meter. 

This 

WARNI

NG 

symbol indicates a 

potentially 

situation,  which if not 

avoided, 

result  in death  or  serious 

injury. 

This 

symbol indicates a 

potentially 

situation,  which if not 

avoided, 

damage to the product. 

This symbol 

that a device  is 

protected 

ghout by double insulation or 

reinforced ins 

Operating Voltage 
Operating  Frequency 

Power  supply 

Operating  Temperature 

Storage Temperature 

Operating  Humidity 

Storage  Humidity 

Operating Altitude 

Weight 
Dimensions 

Approvals 

UL Listed 

90 to  120V 

47 to 63Hz 

9V  battery (receiver) 

41 QF  to  104QF  (5QC to 402C) 

_4°F  to 140°F  (-20°C to 60°C) 

Max  80%  up  to  87QF  (31QC) 

decreasing  linearly  to 50%  at 

104QF  (402C) 

<80% 

7000ft.  (2000meters)  maximum. 

5.90z  (167g) 

8.5" x  2.2"  x  1.5"  (215 x  56 x 

38mm) 

UL CE 

The UL mark does not indicate that 

this product has been evaluated 

for the accuracy of its readings. 

EXTECH  INSTRUMENTS  CORPORA TlON 

warrants  this 

instrument  to  be  free  of  defects  in  parts  and  workmanship  for 

one  year 

from  date  of  shipment  (a  six  month  limited  warranty 

applies  to  sensors  and  cables).  If  it should become  necessary 
to  return  the  instrument  for  service  during  or  beyond  the 
warranty  period,  contact  the  Customer  Service  Department  at 

(781) 890-7440 

ext. 

210 

for  authorization  or  visit  our  website 

www.extech.com 

for 

contact 

information. 

Return 

Authorization  (RA)  number  must  be  issued  before  any  product 
is  returned  to  Extech.  The  sender  is  responsible  for  shipping 
charges,  freight,  insurance  and  proper  packaging  to  prevent 

damage  in  transit.  This  warranty  does  not  apply  to  defects 
resulting  from  action  of  the  user  such  as  misuse,  improper 
wiring, 

operation 

outside 

of 

specification, 

improper 

maintenance  or  repair,  or  unauthorized  modification.  Extech 
specifically disclaims any implied  warranties or  merchantability 
or  fitness  for  a  specific  purpose  and  will  not  be  liable  for  any 
direct,  indirect,  incidental  or  consequential  damages.  Extech's 
total  liabifity  is  limited to  repair  or  replacement  of  the  product. 

The  warranty  set  forth  above  is  inclusive  and  no  other 

warranty,  whether  written or  oral,  is  expressed or implied. 

www 

. ElectricalPartManuals 

. com

Содержание CB10

Страница 1: ...pprovals UL Listed Warranty 90 to 120V 47 to 63Hz 9V battery receiver 41QF to 104QF 5QC to 402C _4 F to 140 F 20 C to 60 C Max 80 up to 87QF 31QC decreasing linearly to 50 at 104QF 402C 80 7000ft 2000meters maximum 5 90z 167g 8 5 x 2 2 x 1 5 215 x 56 x 38mm UL CE The UL mark does not indicate that this product has been evaluated for the accuracy of its readings EXTECH INSTRUMENTS CORPORA TlON warr...

Страница 2: ... side of the transmitter the LED s will be a mirror image of those shown here 3 The tester will not indicate the quality of the ground connection 2 hot wires in a circuit a combination of defects or reversal of ground and neutral conductors Receptacle GFCI Test 1 Before using the tester press the TEST button on the installed GFCI receptacle the GFCI should trip If it does not trip do not use the c...

Страница 3: ... Utilisation Poids Dimensions Max 80 jusqu a 31 C 87 F decroit lineairement jusqu a 50 a 400C 104 F 80 2000 metres 7000 ft maximum 5 90z 167g 8 5 x 2 2 x 1 5 215 x 56 x 38mm Normes de securite approuvees UL CE Norme de securite UL Le label UL n indique pas que ce produit a ete evalue pour la precision de ses mesures Garantie EXTECH INSTRUMENTS CORPORATION garantil que eel instrument est exempt de ...

Страница 4: ... emetteur les LED seront une image inversee de ceux montres ici 3 Le testeur n indiquera pas la qualite du branchement de masse 2 circuits trafiques dans un circuit une combinaison de defauts ou I inversement des conducteurs de masse et neutres Recipient Test GFCI 1 Avant d utiliser Ie testeur appuyez sur Ie bouton TEST sur Ie recipient GFCI installe il devrait remuer S il ne remue pas n utilisez ...

Страница 5: ...1 C 87 F con disminuci6n linear hasta 50 a 40 C 104 F Humedad almacenamiento 80 Altitud de operacion Peso Dimensiones Aprobacion Inscrito en UL Garantia 7000ft 2000 metros maxima 167g 5 90z 215 x 56 x 38mm 8 5 x 2 2 x 1 5 ULCE La marca UL no indica que este producto ha sido evaluado en cuanto a la precision de sus lecturas EXTECH INSTRUMENTS CORPORA TlON garantiza este instrumento para estar fibre...

Страница 6: ...or no indica la calidad de la conexion a tierra 2 alambres con corriente conectados a un circuito una combinacion de defectos 0 conductores tierra y neutro invertidos Prueba de enchufe leFT 1 Ant s de usar el probador presione el boton TEST en el enchufe ICFT instalado el ICFT debe dispararse Si no 10 hace no use el circuito y lIame a un electricista calificado Si se dispara presione el boton RESE...

Страница 7: ...User s manual located between cardboard packaging Adjustable sensitivity for pinpointing the correct breaker w w w E l e c t r i c a l P a r t M a n u a l s c o m ...

Страница 8: ... FIber Optic Meters Water Quality Meters Extech Instruments Corporation www extech com Copyr glltC 20117 21108ExI hInslrumenls CotporaUoo All rightstIIS Ved including tfIe rightollOfXOdu liooin _ IX in rt In anylann aker Finder i I II 7 93950 40010 4 1 nZP4 1111111111111111111111111111111 11TZP4 CB10 w w w E l e c t r i c a l P a r t M a n u a l s c o m ...

Отзывы: