Introduction 

Congratulations on your purchase of this Model CO210 Carbon Dioxide Meter. This meter 
measures and datalogs CO

2

 level, air temperature, humidity, date and time. With visible and 

audible alarms, this is an ideal instrument for indoor air quality (IAQ) diagnosis. This meter is 
shipped fully tested and calibrated and, with proper use, will provide years of reliable service. 

 

Meter Description 

Meter

 

1. CO

2

, Temp and RH sensors (rear) 

2. LCD 

display 

3. Controls 

 
 
 

LCD Display 

 

1. CO

2

 concentration in ppm 

2. Date 

and 

Time 

3. Air 

Temperature 

4. 

% Relative Humidity 

 
 

Symbols 

ppm

 CO

2

 value 

GOOD

 CO

2

 air quality level 

NORMAL

 CO

2

 l air quality level 

POOR

 CO

2

 air quality level 

Air Temp

 Air 

Temperature 

Humidity %

 Relative 

Humidity 

°C or °F

 

Celsius or Fahrenheit 

MAX/MIN

 

Maximum or Minimum reading 

 

Controls 

SET

 Enters 

setup 

mode. 

Saves and finishes settings. 

ESC

 Exits 

setup 

page/mode. 

Terminates calibration / Datalogging 

RESET

 

Press to clear the MAX/MIN. - 
Terminates during RH calibration. 

LOG

 

 

Selects mode or increases value in setup 
Start Datalogging 

MIN/MAX

 

Activates MAX, MIN function.  

 Enters 

CO

2

 calibration with 

SET 

and

 

 

 

o

MAX

MIN

TWA

STEL

CO

2

Humidity

Air Temp. DP WB

GOOD NORMAL POOR

VENT.R

lps

%

cfm/p

ppm

Year

Month

Date

Hour

Min

1

2

3

4

1

2

3

Содержание 793950502105

Страница 1: ...User s Guide CO2 Monitor and Datalogger Model CO210...

Страница 2: ...Date and Time 3 Air Temperature 4 Relative Humidity Symbols ppm CO2 value GOOD CO2 air quality level NORMAL CO2 l air quality level POOR CO2 air quality level Air Temp Air Temperature Humidity Relati...

Страница 3: ...he RESET button for more than 1 second to clear the minimum and maximum value from memory DATA LOGGING The meter can record readings of CO2 temperature and humidity for long time environment monitorin...

Страница 4: ...ode for more than 1 second to enter the setup mode P1 1 CO2 ALARM GOOD LEVEL When entering the setup mode P1 0 and CO2 are displayed on the LCD Press the SET button again to go into P1 1 for setting t...

Страница 5: ...ange the units Press the SET button to confirm the setting or press the ESC button to exit without saving and return to P2 0 P3 0 REAL TIME CLOCK Press the LOG button in P1 0 twice to access P3 0 for...

Страница 6: ...settings Parameter Default P1 1 700ppm P1 2 1000ppm P1 3 1000ppm P2 1 C P4 1 No P5 0 SAMPLING RATE Press the LOG button in P1 0 three times to access P5 0 to set the logging sample rate The available...

Страница 7: ...ation is suggested to be done outdoors on a sunny day with good ventilation and fresh air where the CO2 level is approximately 400 ppm Do not calibrate on a rainy day because high humidity will affect...

Страница 8: ...Humidity 0 1 to 99 9 0 1 3 10 to 90 5 10 or 90 Display LCD Sensor Type CO2 NDIR non dispersive infrared technology Humidity Capacitance sensor Temperature air Thermistor Response CO2 2min for 90 step...

Страница 9: ...if it still appear re calibrate the meter If above two methods faile return for repair E17 ABC mode of CO2 senor has failed and might cause wrong CO2 readings Send back for repair Temp Display E02 Air...

Страница 10: ...lead to serious oxygen deprivation resulting in permanent brain damage coma and even death Regulatory exposure limits ASHRAE Standard 62 1989 1000ppm CO2 concentration in occupied building should not...

Отзывы: