382075 V2.2V 9/10
16
Specifications
General Specifications
Conductor Size
Cable
Φ
55mm. (approx.) Bus Bar 65mm (D) x 24mm (W)
Display
Dual 4-digit 9999 count LCD
Sampling time
0.5 seconds for Voltage and Current; 1.6 seconds for Watts
Overload Indication
‘OL’ displayed on LCD
Power
9V Battery (Heavy Duty Type)
Power consumption
Approx. 28mA
Operating conditions 4
°
C to 50
°
C <85% RH
Dimensions
10.7" (L) x 4.4" (W) x 1.8" (H)271mm (L) x 112mm (W) x 46mm (H)
Weight
22.8 oz. / 647g (with battery)
Safety
For indoor use and in accordance with the requirements for double
insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage
Category III 600V and Category II 1000V, Pollution Degree 2.
AC/DC KW True Power (PF 0.2 - 1.0, 3
φ
3W, 3
φ
4W, 1
φ
2W, and 1
φ
3W) Balanced
Range Resolution Accuracy
(of reading)
Maximum Input
Current Voltage
0 - 99.99KW
0.01KW
±2.0% ±0.5KW
200A
500V AC/DC
100.0 - 999.9KW
0.1KW
±2.0% ±0.5KW
2000A
1000-1200KW 1KW ±2.0%
±5KW
600VAC
800VDC
AC/DC Voltage
(True RMS, Crest Factor < 4, Autorange, Overload Protection 800VAC)
Accuracy (of reading)
Input
Impedance
Range
Resolution
DC, 50 / 60 Hz
40 - 400Hz
0-200V
0.1V
±1.5% ±5dgts
±2.0% ±5dgts
10M
Ω
200-500V
0.1V
±1.5% ±5dgts
±2.0% ±5dgts
500 - 600VAC
500 - 800VDC
1V
±1.5% ±5dgts
±2.0% ±5dgts