9
5. Initial Start-Up Instructions
Brewtus III R (Rotary Pump)
(See previous page if you have the Brewtus III V-Vibration Pump)
After the machine has been removed from the packaging, place it on a level surface.
1. Remove the white protective covering from all parts of the machine.
2. Connect the water line from the machine to your water line connection and turn
on the water supply to the machine. Run the drain line from the bottom of the
machine to your drain line.
3. Plug the machine into a wall socket that matches the three-pronged plug on the
machine. It is important that the machine is grounded. If you have any questions
regarding this please give Whole Latte Love a call at 888.411.5282 and ask to talk
to someone in our technical department.
4. Turn on the main power switch and move the lever on the brew group to the “up”
position. The pump will go on and fill both the steam boiler and brew boiler.
Leave the lever in the “up” position until there is a steady stream of water coming
out of the brew group. If the pump runs for more than 1 minute and no water
comes out of the brew group, please turn off the machine and call Whole Latte
Love technical support at the number above.
5.
Move the lever to the “down” position and let the machine heat up.
6. Always leave the empty portafilter in the brew group so that it will be hot when
using it to brew your next shot.
Note: It will take around 18 minutes for both the brewing boiler and steam boiler to
reach operating temperatures. Please see the brewing tips section for information on
how to get the best out of your new Brewtus III.