background image

     Service Manual 4322 277 00046 is herewith cancelled

HD 7605/A

  

Coffee maker ”Café Essence”

PRODUCT INFORMATION

Voltage
Frequency
Power consumption
Contents jug
Coloursetting

:
:
:
:
:

100, 120, 230V
50 - 60Hz
850 + 550W
1200cc
ceramic white

SERVICE INFORMATION

Thermostat   
Thermal fuse      

REPAIR INSTRUCTIONS
1.

2.

Electrical circuit
When the appliance does not work, check the electrical
circuit. If the thermal fuse or thermostat prove defective,
the complete pump unit has to be replaced.

De-scaling
If the water system is nearly or less clogged by scale
then operate the coffeemaker a few times with vinegar
or with a 10-15% solution of either vinegar-acid, citric
acid or tartar-acid, into cold tap water.

Do not use other de-scaling agents as these may harm
the appliance.
If this procedure does not restore the function, then switch
off the coffeemaker when the acid has passed through
during appr. 3 min. Keep the appliance in this condition
overnight and continue/repeat the cleaning operation.
After the de-scaling procedure, operate the coffeemaker
twice with tap water in order to rinse away any residual
substances.

: 140°C
: 298°C     

switch-off temp

cut-off temp

Philips Domestic Appliances and Personal Care

Pump unit removal
To separate the pump unit from the hotplate unit (item 23),
the two plastic snaps at place A have to be loosened.
Then the pump unit can be lifted out easily.

Exchanging the switch unit
Remove the panel (13) by carefully pushing a small
screwdriver into the chink at point A and moving it towards
to point B (see exploded view). Do not damage the housing.
If the panel has been damaged, get a new one.

3.

4.

MSH coding

8827 605 00000

Published by Philips Domestic Appliances and Personal Care     Printed in The Netherlands      Copyright reserved     Subject to modification

©

00/05

4322 277 00317

PCS 104 827

ROTARY 
SWITCH

AUTO
SHUT
OFF

850W

550W

PRODUCTS MEETS THE REQUIREMENTS REGARDING 
INTERFERENCE SUPPRESION ON RADIO AND TELEVISION.

-  AFTER THE PRODUCT HAS BEEN REPAIRED IT SHOULD 
  FUNCTION PROPERLY AND HAS TO MEET THE SAFETY 
  REQUIREMENTS AS LAID DOWN OFFICIALLY ESTABLISHED 
  AT THIS MOMENT.