If there is air in the gas supply line, it
can take up to two minutes until there
is gas available for combustion. During
this time hold the control knob down
until the flame lights.
3. To ensure even end rapid warm air
distribution as wel as lower surface
temperatures on the heating unit, we
recommend that you operate the
heater with a running - Trumavent
warm air system.
GAS HEATER - ROOM THERMOSTAT
An average room temperature of about
22°C can be achieved without blower
operation with a thermostat setting of 3-5.
For operation with blower, we recommend
a thermostat setting of 4-8.
The exact thermostat setting must be
determined in each case, depending on
how much heat is needed and the design
of your vehicle.
The thermostat probe is underneath the
heater.
Please note that the thermostat will be
adversely affected by cold draughts from
refrigerator vents, gaps below doors, etc.
or by a deep-piled carpet. Always be sure
to avoid problems of this kind, otherwise
satisfactory temperature control cannot
be guaranteed.
Gas Heater - Switching Off
Turn the control switch to '0' (the
automatic ignition will switch off at the
same time).
If the unit is not used for a relatively long
period of time, close off the quick-action
gate valve on the gas pipe and gas bottle.
ELECTRIC HEATER - IMPORTANT
OPERATING NOTES
1. Due to the design, the heater front
case will become hot during operation.
The operator is obliged to ensure that
due care is taken to protect third
parties (small children in particular).
2. The heaters hot air outlet should under
no circumstances become blocked.
3. Never hang clothes or similar in front of
or on top of the heater to dry. This
could cause serious damage to the
heater as a result of overheating. Do
not place inflammable materials near
the heater. Please observe these
instructions for your own safety.
4. When operating a brand new heater for
the first time (or after it has been idle for
a lengthy period) you may temporarily
notice a slight smoke and smell. We
advise running the heater at full power
and thoroughly ventilating the room.
CONTROL PANEL WITH
THERMOSTAT
40
Equipment Use
Содержание 2005 AVANTE
Страница 1: ...Owners Handbook 2005 Touring Caravans...
Страница 4: ......
Страница 6: ......
Страница 36: ......
Страница 68: ...Care Maintenance Explorer Group 2005 Touring Caravan Handbook 67...
Страница 69: ...68 Care Maintenance...
Страница 70: ...Care Maintenance Explorer Group 2005 Touring Caravan Handbook 69 BPW Chassis...
Страница 75: ...74 Care Maintenance...
Страница 76: ...Care Maintenance Explorer Group 2005 Touring Caravan Handbook 75...
Страница 78: ......
Страница 82: ......
Страница 110: ......