49
13.2 SAFETY FEATURES
13.2.1 DOUBLE SOLENOID VALVE
The prjector has been fitted with two solenoid valves in series. Next to the basically neccessary flame
valve, a second safety valve has been installed. Without an electrical ignition, these valves cannot
open.
13.2.2 WATCHDOG-TIMER
An internal watchdog-time constantly checks the function of the processor. Should it be jammed during
any ignition routine or similiar, a safety interruption of the device will occur, before a reset.
13.2.3 MECHANICAL BLOCK
A mechanical block in both movement directions prevents the device from driving to any angle above
120° in both directions.
13.2.4 AUTOMATIC SAFETY CHECKS
Automatic safety checks after startup and during usage, check the device for any errors. For example,
it will check whether the head is blocked (drivetest) or if the system has a leak.
13.2.5 DEACTIVATING THE OUT ER ANGLES
The X2 Wave Flamer allows single angles to be blocked before a show, so that these can't be
accessed. This can already prevent certain risks before the show, by protecting objects placed in
these angles around the device.
13.2.6 ARMING THE DEVICE
The device can be turned armed by radio. Therefore it isn't neccessary for persons to linger in the
closer vicinity of the device, to arm it for use.
Only afte this occurs, the pressure needed for usage will be built. This is constantly monitored.
13.2.7 POW ER OUTAGE
In case of a power outage, the device will interrupt running sequences and the show. After switching it
back on again, it will do the usual startup, as long as the key switch was in the ON position. It will start
in the previus mode, meaning that a device that was turned armed before the power outage, will also
start up in armed mode again.