Status-LEDs of the X2 Wave Flamer
FULL
Shows that the pumping unit has reached usage pressure.
PUMP
Is only lit if the pump is working. Should only be lit in armed-mode.
ERR
This LED indicates any errors with the device. If lit, the fuel canister may be empty.
The Wave Flamer may not be used if this LED is lit, since it may lead to damages of
the device.
Please note the errorcode and contact the manufacturer.
RX
This LED flashes if a radio signal from the transmitter is received.
DMX
If DMX is integrated into the device, and is ready for use, this LED will be lit. If the
projector receives DMX signals, it will flash for confirmation.
BAT
Shows the status of the power supply. If it is lit permanently, the power is okay. If it
begins to flash, the device does not receive sufficient power. This may be caused by
a defunct mains supply.
ARMED
The three middle LEDs are lit if the device is in armed-mode. During this time, be
cautious when using the device, and make sure all safety distances are being
adhered to.
3.5.4 ANTENNA SOCKET
A fitting antenna with BNC connector can be mounted to the BNC antenna socket for radio use. We
recommend the use of original antennas.
The antenna is used to receive data. Pinching or breaking the antenna or its cable can lead to
damages, and should therefore be avoided. During use, make sure that the antenna is safely mounted
and placed upright, to guarantee the best possible radio reception.
Water or moisture entering the antenna socket can drastically decrease the radio reception.
3.5.5 PROGRAMMING SOCKET
Combined with the bootloader programming cable (sold separately) updates of the devices software
can be made by yourself.
3.5.6 DMX-CONNECTORS
Via the 3 pole XLR connectors, a DMX controller can be connected to the Wave Flame. The outgoing
socket can be used to forward the DMX signal to the next Wave Flamer.
Pin-configuration of the DMX-connector
Pin 1
GND
Pin 2
B
Pin 3
A
3.5.7 ON / OFF SW ITCH (POW ER)
Allows you to switch the Wave Flamers power supply on or off. After switching the wip switch on, the
key switch must be at least switched on shortly, to start up the device.